Jungheinrich ETM/V 10-12 Forklift Truck Pressure Relief Valve Setting

Jungheinrich ETM/V 10-12 Forklift Truck Pressure Relief Valve Setting

 

Related Contents:

Jungheinrich JETI ForkLift Judit-4 v4.37 4.34 2023 Free Download

Jungheinrich JETI ET 4.37 4.34 EPC 2023 Free Download

2023 Jungheinrich Forklift JETI SH v4.36 v4.34 Service Free Download

 

 

Bleed the hydraulic system

Set the pressure relief valve (1) to nominal load pressure +15 bar when the hydraulic system is at operating temperature.

 

After setting the valve, secure the setscrew with sealant.

The pressure relief valve factory pre-setting is 200 bar

 

Bleeding the Hydraulic System

The hydraulic system is bled via the bleed screw on the lift cylinders.

Torque the M6 bleed screw to M, = max. 7 Nm.

Line Break Safety Device Control

The maximum permissible lowering speed in the mast lift is 0.6 m/s.

Raise the lowering speed via the setscrew (2) until the line break safety devices are activated.

Jungheinrich ETMV 10-12 Forklift Truck Pressure Relief Valve Setting

Do not completely unscrew the setscrew.

After testing, the lowering speed must be reset

lf the tolerance level is exceeded check and adjust the line break safety device setting, if necessary replace the line break safety device.

 

Lowering Speed Setting

When checking and setting the lowering speed, the load pickup device in the mast lift must be at 0.5 m/s +15%.

 

To reduce the lowering speed turn the setscrew (2) on the flow controller clockwise.

After setting the speed, secure the setscrew with sealant.

 

For more Jungheinrich trouble repair case,please refer to Jungheinrich Trouble Repair

Visited 1 times, 1 visit(s) today