DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 BSI

This article show a guide on how to use DiagBox Lexia P2000 to program new keys for Peugeot 307 BSI.Hope it Helps!

 

Preparations:

DiagBox Software Free Download All Version Here

How to Install DiagBox v8.01 Software

Lexia3 PP2000 Interface

 

Preocedures:

Connect interface to vehicle and run DiagBox software

Select “PEUGEOT”

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (1)

Vehicle model “307”

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (2)

After vehicle idenfitication,it will show you the VIN,and ask “IS THE VIN READ ON THE VEHICLE CORRECT?”,click “YES” icon to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (3)

Then select “DAIGBOX”

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (4)

Select “REPAIR”

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (5)

Then DiagBox will each control units

After control units test completing,click “BSI”

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (6)

Select “PACK REPARATION”

Select “LEARN”

Select “PROGRAMMING OF KEYS”

 

Key programming procedure:

To program the keys,you must have

1.The customer’s confidential card

2.All of the vehicle’s keys

WARNING:The keys which are not programmed in this programming procedures will no longer permit starting of the engine.If a new key is added,it is possible to reprogramme all of the keys.

Click “Yes” icon to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (7)

In order to program the keys,the code indicated on the customer’s confidential card must be entered.

WARNING:If a confidential code error occurs,programming will be prohibited.

 

You can confirm the confidential code by means of the procedure in force in your country.

INFORMATION:Whether you are in the process of downloading replacing,or initialising the BSI,the diagnostic tool will automatically use the code already entered at the time of the intialising of the confidential code.

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (8)

Enter the EXAT code indicated on the customer’s confidential card

WARNING:There is no letter “o” or letter “i” in the confidential codes

Click “Yes” to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (9)

Confidential code correct

The built-in system interface is ready for programming of the keys

Click “Yes” to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (10)

Now enter the key number to learnt

The nunber of keys to programmed can not exceed 5

Click “Yes” to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (11)

Switch off the ignition

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (12)

You have 15 seconds within which to switch on the ignition positive (+APC) using the key to be programmed.

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (13)

Key programmed.Switch off the ignition and take out the key

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (14)

For program next key,you need to insert the next key in the ignition

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (15)

The switch off the ignition

You have 15 seconds within which to switch on the ignition positive (+APC) using the key to be programmed.

Key programmed.Switch off the ignition and take out the key

Number of keys to be programmed=2

Number of keys programmed=2

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (16)

IMPERATIVE:Before making any attempt to start the engine-Check that the handbrake is on

For an automatic gearbox,check that the gear lever is in position “P”(Park)

For a manual gearbox,check that the gear lever is in neutral

Click “Yes” to continue

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (17)

 

Pesynchronise the High Frequency Remote Controls

Procedures:

1.Switch off the igniton and take out the key

2.Wait one minute without pressing the buttons of any remote control

3.Insert a key in the steering lock,turn it to ignition positive (IGN+)

4.Within 1 seconds,press the locking button for 2 seconds syntax error @*10syntax error @*5

5.Switch off the ignition and take out the key

6.Repeat the procedure with the other keys from point N*3.otherwise move on to point N*7

7.Wait 30 seconds,the remote controls are active

This procedure can be used at any time and without using diagnostic equipment

WARNING:Pressing one of the buttons of a remote control while it is desynchronised resultes in the switching of the built-in systems interface to antiscanning mode for one minute

Resynchronisation is prohibited during this phase.

DiagBox Lexia 3 PP2000 Program New Keys for Peugeot 307 (18)

Done!

Visited 1 times, 2 visit(s) today