Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution
Error description WATER IN FUEL
Fuel filter water level sensor: the voltage of sensor measured by ECU is out of the target range

Related Contents:
2023 Deutz Serdia 4.0 Serdia 2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Serpic EPC Parts Catalogue 2014 2012 Free Download
Error codes
DEUTZ-Errorcode: 87
BlinkCode (short-long-short): 2 – 2 – 8
SPN: 97
Possible FMI:
3: Voltage to high or short circuit to +Ubatt
4: Voltage to low or short circuit to -Ubatt
- Errormode not identifiable
- Errormode not identifiable
Error detection
Errorlamp shows permanent light. Entry in errormemory.
Possible reason for error cable break or short circuit, sensor defective, connection cable
damaged
Take actions for error repair
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it other error properties
System reaction: Warning, substitute value
Behaviour error lamp: permanent light
Selfhealing: yes
Signal Priority: 1