Liebherr Machine P1121 DEF Pump Out of Service Error Solution

Here is the instruction show you guide on how to solve Liebherr machine trouble code SCR system DEF pump out of service error.

 

Related Contents:

2026 LIEBHERR LiDIA Diagnostic Software

Liebherr Diagnostic Tool with 9 Pin Cable

 

 

Reason:

Error is active when, despite activation of the urea pump, no build-up of pressure can be detected on the DEF side of the urea pump to the SCR injector

  • Urea pump does not build up any pressure in the DEF line to the injector or cannot suck from the DEF tank to the urea pump
  • Maximum time is exceeded during the filling of the DEF line to the injector

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (1)

 

Troubleshooting

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (2) Liebherr Machine P1121 DEF Pump Out of Service Error Solution (3) Liebherr Machine P1121 DEF Pump Out of Service Error Solution (4) Liebherr Machine P1121 DEF Pump Out of Service Error Solution (5) Liebherr Machine P1121 DEF Pump Out of Service Error Solution (6)

 

 

Consequence:

As the P1121-00 failure is emission relevant, the inducement process starting with P1187-00 “Inducement system – Warning (SCR failure) will begin, leading to a power reduction if the failure is not solved.

 

  • If a second occurrence of the failure comes back, this leads to a repeated offense issue which means that the engine will stay blocked in the latest stage of inducement. As a consequence, Service Technician is needed to remove the power reduction.

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (7)

 

BMK

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (8)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (9)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (10)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (11)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (12)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (13)

 

 

Component Location

D956-D966 A7-04 (SCR only)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (14)

D956-D966 A7-05 StageV (SCR Filter)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (15) Liebherr Machine P1121 DEF Pump Out of Service Error Solution (16)

 

 

D9512 A7 04-05-StageV

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (17)

 

Primary (A700)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (18)

 

Secondary (A760)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (19)

Liebherr Machine P1121 DEF Pump Out of Service Error Solution (20)

Visited 9 times, 8 visit(s) today