Deutz EMR3 Trouble Code 78/ 190 Speed Sensor Signals Out of Phase

This instruction show you guide on how to solve Deutz EMR3 trouble code 78/ 190 EngMOfsCaSCrS Speed sensor of crankschaft and camschaft: the received signals are out of phase.

Deutz EMR3

Related Contents:

Deutz DECOM

2023 Deutz Serdia 4.0 Serdia 2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Serpic EPC Parts Catalogue 2014 2012 Free Download

 

Error Codes

DEUTZ-Errorcode: 78

BlinkCode (short-long-short): 2 – 1 – 3

SPN: 190

 

Possible FMI:

2: data stream is defective

  1. Errormode not identifiable
  2. Errormode not identifiable
  3. Errormode not identifiable

 

Error Detection

Error lamp shows permanent light. Entry in error memory.

 

Possible reason for error

Speed signals of crank-shaft and cam-shaft are phase-shifted,sensor wheel installed in wrong position, sensor wrong wired

 

Take actions for error repair

Check position from crankschaft sensor wheel to camschaft sensor wheel, polarisation crankschaft or camschaft sensor,check position of sensor wheel and if necessary correct it, check

cabling and if necessary correct it other error properties

 

System reaction:

Warning, not possible to start engine

Behaviour error lamp: permanent light

 

Selfhealing: no

Signal Priority: 4

 