This instruction show the basic operation of how to use VCP System to do VW DPF emergency regeneration.Hope this guide is helpful to you!
Preparations:
How to Install VCP System Diagnostic Tool Software
VCP System Professional Diagnostic Tool Software Download
Vehicle Model Supported:
PQ35/PQ45- CAN UDS
VW T5 BNZ/BPC, Audi A4 8E–K Line
Passat 3B / BGW–K Line
2.0 CR (CBAB, CBBB,CEGA)–CAN TP 2.0
2.0 CR EDC17–CAN UDS
Procedures:
Firstly,you need to build connection between your vehicle and VCP software,connect interface to vehicle,after software connection,select “Guided functions assistant”.
Select “DPF” from right bar,then select “DPF emergency regeneration(1.4,1.9,2.0,2.5 TDI PD)”
The procedures starts emergency regeneration function DPF particulate filter
Conditions:
Ignition on
The engine is idling
Engine temperature above 50℃(Block 2,item 4)
Filling DPF below specification (Block 75,item 3)
(DPF has to be changed if fill is exceeded normative)
The turbine exhaust temperature-700℃(block 75,position 1)
Duration 15-20 minutes
The status of regeneration of 0000000 means that the regeneration is completed,the status of 000001 means that the regeneration is performed.
Select car models
Procedure will be started
Turn on ignition
Start the engine
After pressing “Next” the procedure will begin.
And then you need to wait for processing completed
Magneti Marelli 49FB – Fiat ECU Pinout More ECU PINOUT Components: ECU Modules Repair…
After ECU reparogramming,it is necessary to write new engine number and machine ID into ECU.So…
PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution Related Contents: 2024 InPower V14.5…
The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…
MTU DiaSys diagnostic software is professional on MTU engine diagnostics and programming.But seems that is…
This instruction show you guide on how to use JPRO Diagnostic to do aftertreatment injector…