This instruction show you guide on how to solve Liebherr machine emergency stop ignition on while emergency stop is activate error.

 

Related Contents:

2026 LIEBHERR LiDIA Diagnostic Software

Liebherr Diagnostic Tool with 9 Pin Cable

 

When ignition is switched on, the ECU receives the ignition signal on X2 – 30, and at the same time, the time delay relay waits and activates after a minimum delay of 200 ms.

At this point, if all emergency stops are deactivated, the 24 V signal is sent to the ECU to indicate that it is ready to start.

 

The process is Impossible if one of this condition is active:

– E-Stop open

– Relay timer activation less than 200ms

– Fault code active ( red lamp, amber lamp)

 

More repair case for Liebherr machine,please refer to Liebherr trouble repair

auto

Recent Posts

How to Solve Doosan Machine U043D CAN Receive Frame Counter Error

This instruction show you guide on how to solve Doosan machine trouble code U043D message…

1 week ago

AGCO Machine Trouble Code SPN 1485 – FMI 03 Solution

Here is the instruction show you guide on how to solve AGCO machine trouble code…

2 weeks ago

Detroit DD13 J1939 Wheel-Based Vehicle Speed Sensor Signal Missing

Detroit DD13 EPA10 (2010-13) trouble code SPN 84 FMI 13 (MCM) J1939 Wheel-based vehicle speed…

4 weeks ago

How to Solve Caterpillar C9 Vehicle Speed Signal Invalid?

This instruction show you guide on how to solve Caterpillar C9 engine trouble code 36…

4 weeks ago

Kubota L3301 L3901 Excavator Safety Valve Setting Pressure Test

Kubota L3301 L3901 Excavator Safety Valve Setting Pressure Test Using Injection Nozzle Tester 1 Remove…

1 month ago

JCB 200X Series Machine Reduced Power Mode Engine Derate

JCB Engine Fault Derate When a fault is detected, the ECU determines the severity of…

1 month ago