MANITOU MT6034 Telehandlers PWP System Deactivation Tests

This instruction show you guide on how to do deactivation test for MANITOU MT6034 telehandlers PWP system.

MANITOU MTA 6034

Related Contents:

2026 Manitou I.V Interactive View Diagnostic Software

 

 

To test the PWP System de-activation logic:

1 Turn the key switch to “OFF” and wait for the engine to stop. Then turn the key switch back to “ON.”

The PWP switch lamp and the parking brake switch lamp should both be illuminated.

 

2 Turn the key switch to “OFF” and then turn the PWP rocker switch to “OFF.” Turn the key switch back to “ON.”

The PWP switch lamp should be flashing and the parking brake switch lamp should be on continuously.

 

3 Start the engine and apply the service brakes.

The PWP switch lamp and the parking brake switch lamp should go off after approximatelythree seconds of brake pedal application.

 

If PWP System fails to perform properly, troubleshoot using the chart on page 67. Contact your dealer for service information and parts.

 