How to Solve Deutz EMR3 71 / 2791 / EGRCD_SigNpl Error?

This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 / EGRCD_SigNpl error.

Deutz EMR3

Error description EGR ACTUATOR

Actuator of the external EGR valve: the ECU detects no load or excess temperature of the ECU component for power supply of the connected components.

 

 

Related Contents:

Deutz DECOM

2023 Deutz Serdia 4.0 Serdia 2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Serpic EPC Parts Catalogue 2014 2012 Free Download

 

 

Error codes

DEUTZ-Errorcode: 71

BlinkCode (short-long-short): 4 – 1 – 5

SPN: 2791

 

Possible FMI:

  1. Errormode not identifiable
  2. Errormode not identifiable

5: current to low or broken wire

2: data stream is defective

 

Error Detection

Errorlamp shows permanent light. Entry in errormemory.

 

Possible reason for error

Cable break or excess temperature, sensor defective, connection cable demaged

 

Take actions for error repair

Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it

 

Other error properties

System reaction: Warning, shutoff output, power reduction via second topcurve?

Behaviour error lamp: permanent light

Selfhealing: no

Signal Priority: 3

Measurement @ errortime: shut off value

 

For more topics about Deutz repair case,please refer to:Deutz Trouble Repair.

Visited 7 times, 7 visit(s) today