This test report from G-scan 2 team on how to use G-Scan 2 diagnostic tool to initialize headlight driver module and teach in LEDs in headlight.If you want to check more G-Scan 2 test report,please check here:G-Scan 2 Test Projects.
How to Initialize Headlight Driver Module:
Connect G-Scan 2 diagnostic system tool to vehicle OBD port, and enter [DIAGNOSIS] menu,then select [BMW]–>[X Series]–>[X3 (F25) (2010-present)]–>[Body]–>[FRM(Footwell module)]
Select [OK] to continue
Select [Special Function]
Select [Initialise the headlight driver module and teach in LEDs in headlight]
Now in progress
The TMS on the left-hand side has been initialized.
Then select [OK] to continue,and wait for progress
Until it prompt you “The TMS on the right-hand side has been initialised”
Then press [OK],it will in progress
Adaptation of LED lights in the left headlight has been started and takes approx.10 seconds,please wait..
Adaptation of the LED lights in the left headlight has been performed,the press[OK] to continue
The headlight driver module (TMS) can be tested in the following way:
-Switch on ignition
-Switch the light off and on
A reference run must be visible
If the reference run i not visible the service function must be performed again
Press [OK] to continue
G-scan 2 in progress
Service function finished
Done!
Deutz engine EOL test (end of line) is required to ensure the EAT functionality. Conditions…
This instruction show you guide on how to solve Scania truck articulation control system ACS…
Magneti Marelli 49FB – Fiat ECU Pinout More ECU PINOUT Components: ECU Modules Repair…
After ECU reparogramming,it is necessary to write new engine number and machine ID into ECU.So…
PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution Related Contents: 2024 InPower V14.5…
The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…