How to Solve JCB Excavator P0615-13 Starter Relay Open Circuit Error

Here is the instruction show you guide on how to solve JCB excavator P0615-13 trouble code starter relay open circuit.

 

Related Contents:
2025 JCB ServiceMaster 4 v25.1.0 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

JCB Diagnostic tool

 

 

Possible Cause:

1 Faulty starter relay.

2 Starter relay not connected to machine

3 Faulty wire harness.

4 Terminal back out from starter relay base.

5 Terminal back out from MECU wire harness connector.

 

Diagnosis:

1 Check the starter relay coil resistance. Resistance values shall be 220 Ω.

2 Check starter relay connected to relay box. Refer below photograph.

How to Solve JCB Excavator P0615-13 Starter Relay Open Circuit Error (1)

Check the connectivity between wire no 8065 & wire no 8067 in MECU wire harness connector for the terminal back out. Refer below photograph.

How to Solve JCB Excavator P0615-13 Starter Relay Open Circuit Error (2)

Check the connectivity between wire no 8065 & wire no 8067 to verify the terminal back out in the starter relay base (Relay Box).Refer below photograph.

How to Solve JCB Excavator P0615-13 Starter Relay Open Circuit Error (3)

 

Corrective Action:

1 Replace faulty starter relay.

2 Replace the wire harness or correct the open circuit in the wire harness if terminal back out is there.

 

More topics for JCB machine,please refer to:JCB Machine Trouble Repair.