Valtra BH Series 140-210 Internal lateral Inertial Sensor Recalibration

This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA 28 – SPN 520219 FMI 13 internal lateral inertial sensor needs recalibrating.

Valtra BH Series 140-210

Related Contents:

2025 AGCO EDT (Electronic Diagnostic Tool) v 1.128 v1.75 Free Download

AGCO 2×4 CANUSB Diagnostic Kit

 

 

The guidance controller has detected the signal from the internal inertial sensor which measures lateral acceleration is outside of calibration limits.

 

The guidance controller uses inertial sensor to assist with guidance and improve accuracy on undulating terrain. The inertial sensors are inside the guidance controller and are unserviceable in the event of failure.

 

Failure Mode Indicator

FMI 13 – Out of calibration

 

Diagnosis and Solution

1 REPOWER THE GUIDANCE CONTROLLER.

a Disconnect power to the guidance controller via the appropriate switch for 30 seconds.

b Reconnect power to the guidance controller.

 

Expected Result:

Diagnostic fault code no longer exists.

 

Results:

  • YES – The system reported a false diagnostic.

Repair: Report false diagnostic.

 

Proceed to step 2.

  • NO – The guidance controller has a hardware failure.

Repair: The guidance controller requires replacement per customer’s warranty/replacement plan.

STOP.

 

2 REPORT FALSE DIAGNOSTIC

a Report the false diagnostic to AGCO Technical Support.

b Customer may resume operation of system.

c Ask customer to monitor system in case the error reappears.

STOP.

Visited 2 times, 2 visit(s) today