Flame monitor

Error identification

The flame disappears in the MAX position.

 

Cause

The flame disappears when the temperature exceeds 90°C and the auxiliary heater is in the MAX operating mode.

 

Notes

Action

Check that the exhaust pipe for the combustion air fan is not blocked.

Check the combustion chamber.

Check the fuel supply.

Check the flame monitor.

Check the glow plug. See the Internal electrical diagram under Connections. Measurement points 1 and 2 in harness-to-harness connector B for the control unit.

 

Resistance:

2 +/- 0.2 ohms.

Instructions for the checking procedures are found in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

 

ATA 154

Flame monitor

Error identification

The flame disappears in the HIGH position.

 

Cause

The flame disappears when the temperature exceeds 90°C and the auxiliary heater is in the HIGH operating mode.

 

Notes

Action

Check the fuel supply.

Check that the exhaust pipe for the combustion air fan is not blocked.

Check the combustion chamber.

Check the flame monitor.

Check the glow plug. See internal electrical diagram. Measurement points 1 and 2 in harness-to-harness connector B for the control unit.

 

Resistance:

2 +/- 0.2 ohms.

Instructions for the checking procedures are found in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

 

ATA 155

Flame monitor

Error identification

The flame disappears in the INTERMEDIATE position.

 

Cause

The flame disappears when the temperature exceeds 90°C at ATA 1 or 85°C at ATA 2 and the auxiliary heater is in the INTERMEDIATE operating mode.

 

Notes

Action

Check the fuel supply.

Check that the exhaust pipe for the combustion air fan is not blocked.

Check the combustion chamber.

Check the flame monitor.

Check the glow plug. See the Internal wiring diagram under Connections. Measurement points 1 and 2 in connector B for the control unit.

 

Resistance:

2 +/- 0.2 ohms.

Instructions for the checking procedures are found in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

ATA 156

Flame monitor

Error identification

The flame disappears in the LOW position.

 

Cause

The flame disappears when the temperature exceeds 95°C at ATA 1 or 80°C at ATA 2 and the auxiliary heater is in the LOW operating mode.

 

Notes

Action

Check the fuel supply.

Check that the exhaust pipe for the combustion air fan is not blocked.

Check the combustion chamber.

Check the flame monitor.

Check the glow plug. See the Internal electrical diagram under Connections. Measurement points 1 and 2 in harness-to-harness connector B for the control unit.

 

Resistance:

2 +/- 0.2 ohms.

Instructions for the checking procedures are found in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

ATA 164

Flame monitor

Error identification

Prohibited voltage level in the circuit for the flame monitor.

 

Cause

Open circuit in the flame monitor circuit.

 

Notes

Action

Check the flame monitor.

The checking procedure is described in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

 

ATA 165

Flame monitor

Error identification

Prohibited voltage level in the circuit for the flame monitor.

 

Cause

Short circuit in the flame monitor circuit.

 

Notes

Action

Check the flame monitor.

The checking procedure is described in the work description in Multi under 18-90 “H13, ATA Auxiliary heater – air”.

 

For more information about Scania truck,please refer to:Scania Trouble Repair.

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

1 week ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

2 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago