Here is the instruction show you guide on how to solve Scania Truck ATA 152 fault code safety time flame monitor does not detect any flame.
Related Contents:
2026.03 Scania SDP3 V2.69.3 V2.40 Diagnostic Software Free Download
Error identification
The safety time for starting attempts has been exceeded.
Cause
The flame monitor does not detect any flame when attempting to start.
Action
Check the fuel supply.
Check that the exhaust pipe for the combustion air fan is not blocked.
Check the flame monitor.
Check the glow plug. See the Internal electrical diagram under Connections. Measurement points 1 and 2 in harness-to-harness connector B for the control unit.
Resistance:
2 +/- 0.2 ohms.
Instructions for the checking procedures are found in the work description in WSM under 18-90 “H13, ATA Auxiliary heater – Air”.
For more information about Scania truck,please refer to:Scania Trouble Repair.
It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…
Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…
This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…
Here is the instruction show you guide on how to install the left-hand drum bearing…
This instruction show you guide on how to remove and replace loader lift ram for…
This instruction show you guide on how to solve Caterpillar C9 engine 31 84-1 fault…