Scania 4 series do not have a coordinator and uses VCI 1 to connect to the vehicle to run SD2/SP2. To read engine data in real time with for example Scanina XCOM you have to connect to CAN with VCI 2. To do that you need a “homemade” VCI-cable, see below, and a software-fix to connect to the engine control unit (ECU).
Related Contents:
2024.043 Scania SDP3 V2.60.1 V2.40 Diagnostic Software Free Download
2023 2018 Scania Multi EPC Parts Catalogue Free Download
It also works with DMecNet, CDev, Gadget and other SCOMM based programs.
1.You need:
Standard CAN connector (Scania P/N 1349719)
4 cables (approx. 40cm)
2 alligator clip
Standard VCI connector
2.Connect the wires according to pictures
Pin 16 to red alligator clip
Pin 4 to black alligator clip
Pin 6 and 14 to CAN connector
3.Set the tester address and search mode in XCOM These changes will make XCOM, SDP3, Gadget, CDev and DMecNet to only scan for EMS on the CAN bus. No other ECUs will be found!
Open Options in XCOM (Options menu -> Options)
Set Tester address to “F9”
Change search mode to “S6 PRESAMM (Physical request ECU 0x00)”. Select OK on the warning.
Press OK to accept changes.
Restart XCOM
4.Connect the “Homemade” VCI cable to the vehicle under the fuse box. Connect VCI2 to the VCI connection.
This instruction show you guide on how to solve Scania truck articulation control system ACS…
Magneti Marelli 49FB – Fiat ECU Pinout More ECU PINOUT Components: ECU Modules Repair…
After ECU reparogramming,it is necessary to write new engine number and machine ID into ECU.So…
PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution Related Contents: 2024 InPower V14.5…
The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…
MTU DiaSys diagnostic software is professional on MTU engine diagnostics and programming.But seems that is…