Heavy Equipment Repair

Liebherr ECU2 D966 D9512 Engine P1162 Fault Code Solution

Here is a instruction show you guide on how to solve Liebherr ECU 2 D966 D9512 engine fault code P1162 module sensor communication error.

 

Reason:

Faulty sensor(s) (mechanical and electrical components, power supply, set value, measuring range)

 

Related Contents:

2026 LIEBHERR LiDIA Diagnostic Software

Liebherr Diagnostic Tool with 9 Pin Cable

 

 

 

Troubleshooting

Check wiring for proper connection and contact as well as for damage (terminal connections, connectors, module connections)

Check voltage supply for sensor

Information for engines with serial number UP TO 2018 xx xxxx (12/31/2018):
In the event of failures of NH3 sensors (ID no. 10144038) on the exhaust treatment system of Stage IV engines, the NH3 control unit (ID no. 10144039) must also be replaced ONCE to improve the service life of the NH3 sensor.
The sensor will come with an extended heat shrink tubing for improved protection of the trim resistance.This spare parts information applies for engines with a serial number up to 2018 xx xxxx (12/31/2018) : all engines with a year of manufacture starting from 2019 are already equipped with the latest version.
• In the event of a sensor failure, the sensor control unit must be replaced ONCE with a new sensor control unit.
• No active conversion is carried out. Replacement only in the event of failure.
• A repair kit with the ID 13489562 is available, it includes the sensor and sensor control unit.

 

Consequence:

Possible failure SCR system

 

Component Location

EATS All versions

D956-D966 A7-04 (SCRonly)

D956-D966 A7-05 StageV (SCRFilter)

EATS All versions

D9512 A7 04-05-StageV

Primary (A700)

Secondary (A760)

 

More repair case for Liebherr machine,please refer to Liebherr trouble repair

auto

Recent Posts

AGCO EEM5 DEF Suction Module Tank sensor (CAN)

AGCO EEM5 DEF Suction Module Tank sensor (CAN) The DEF suction module with the CAN-bus…

3 days ago

How to Remove Threshing Drum for CLAAS Lexion 480 Combine

This instruction show you guide on how to remove the threshing drum for CLAAS Lexion…

5 days ago

Hitachi ZX890-7 Excavator Service Menu Display

This instruction show you guide on how to display service menu for Hitachi ZX890-7 excavator.…

1 week ago

JCB 200 Series Excavator ATS Setup and Calibration Procedure

Here is the instruction show you guide on how to do Advanced Tool Select and Basic…

2 weeks ago

How to Solve Liebherr D966 D9512 Trouble Code P1161 Resistance Error

Here car-auto-repair.com show you guide on how to solve P1161 trouble code on resistance error…

2 weeks ago

AGCO EEM 5 Dosing Module

AGCO EEM Dosing module   Description The dosing module (DM) is installed in the exhaust…

3 weeks ago