Heavy Equipment Repair

JCB Tier 4 Engine Start Relay High Side Voltage and Current Above Normal

Here is the instruction show you guide on how to solve JCB Tier 4 engine SPN 1321, FMI 3 and SPN 1321, FMI 6 start reply high side voltage/current above normal.

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

 

Start Relay High Side Voltage Above Normal

Description

The start relay high side voltage is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

 

 

Start Relay High Side Current Above Normal

Description

The start relay high side current is above the normal operating range.

 

Possible causes are:

The start relay wiring is defective.

The start relay is defective

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

Check the start relay wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).

Check the operation with another start relay to see if the relay is defective.

More repair case for JCB,please refer to:JCB Trouble Repair

auto

Recent Posts

Doosan Bobcat Machine Electric Fault Troubleshooting Guide Tip

This instruction show you guide on how to solve Doosan and Bobcat Electric problems can…

19 hours ago

How to Download and Install JCB DLA 2.0 Driver?

It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…

7 days ago

How to Solve Deutz EMR3 Engine 94 /523239/FrmMngDecV1?

Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…

1 week ago

How to Solve AGCO Machine Trouble Urea pressure too high?

This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…

2 weeks ago

How to Install Left-hand Drum Bearing Assembly for CLAAS LEXION 480

Here is the instruction show you guide on how to install the left-hand drum bearing…

3 weeks ago

How to Remove and Replace Loader Lift Ram for JCB 3CX 4CX Machine

This instruction show you guide on how to remove and replace loader lift ram for…

4 weeks ago