JCB Tier 4 Air Filter Pressure below Normal Error Solution

This illustration show the solution JCB stage V Tier 4 SPN107 FMI 18,air filter pressure below normal error.

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

Description

The air filter pressure is below normal operation range.

 

Possible causes are:

The air filter is blocked.

The air filter pressure sensor wiring is defective.

The air filter sensor is defective.

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

Change the air filter.

To check the electrical defects, check intake the air filter pressure sensor, the sensor wiring and the controller input: First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

 

Check the air filter pressure sensor wiring, the connectors and the contact surfaces of the connector pins (possible oxidation)

.

Check the operation with another air filter pressure sensor to see if the air filter pressure sensor is defective.

 

More repair case for JCB,please refer to:JCB Trouble Repair

auto

Recent Posts

How to Solve Liebherr D966 D9512 Trouble Code P1161 Resistance Error

Here car-auto-repair.com show you guide on how to solve P1161 trouble code on resistance error…

2 days ago

AGCO EEM 5 Dosing Module

AGCO EEM Dosing module   Description The dosing module (DM) is installed in the exhaust…

5 days ago

Caterpillar C9 Trouble Code Trouble Code 64-2 Secondary Engine Speed Loss of Signal

Here is the instruction show you guide on how to solve Caterpillar C9 fault code 64-2…

2 weeks ago

How to Bleed Air from the Fuel System for FENDT 900 Vario Tractor

This instruction show you guide on how to bleed air from the fuel system for…

3 weeks ago

Doosan Bobcat Machine Electric Fault Troubleshooting Guide Tip

This instruction show you guide on how to solve Doosan and Bobcat Electric problems can…

1 month ago

How to Download and Install JCB DLA 2.0 Driver?

It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…

1 month ago