How to Update DiagBox Software for Lexia & PP2000

This article introduce the method of how to update DiagBox software for Lexia & PP2000:

Update Diagbox V8.17 to V8.37
Update Diagbox V8.35 to V8.38
Update Diagbox V8.38 to V8.42
Update Diagbox V8.42 to V8.46

PSA DiagBox Diagnostic Software Free Download

 

Before you start updating low version to high version,you need to download update file you need!It include

“APP_Update_817-837.EXE”,”APP_Update_835-838.EXE”,”APP_Update_838-842.exe”, “APP_Update_842-846.exe” and “APP_Update_846-847.rar”. Those executables are intended to update Lexia and  PP2000 components of DiagBox from versions 8.17+ or 8.35 respectively, to the latest 8.42 and will bring Lexia v500.74 and PP2000 v600.80 to latest fixes or support level.

 

Note:This software provided and the procedures proposed are intended for personal,educational and experimental use.Please carry out this procedure at your own risk.

 

DiagBox Update File Download:

This should only be attempted if you have installed the “APP-835.7z” or if your installation is DiagBox v8.17 or v7.81 or higher.

 

File 1 is an update for the APP folder for DiagBox v8.17, files 2, 3, 4 and 5 can be used to update up to 8.46. DiagBox versions will not change after applying updates 1, 2 and 3. Only file 4 and 5 will change the version number to 07.846 and 07.847.

 

*- Ensure you have a backup copy of the file “C:\AWRoot\bin\fi\APPDIAG.SYS” before you start.

 

1- APP_Update_817-837.exe 75.2 MB     Password = Simple

https://mega.nz/#!Z0EHmRwB!T4QsYzZxrNiatSoRlacjCw7oghPpb0H200MO03BM2jg

 

2- APP_Update_835-838.exe 39.4 MB     Password = Simple

https://mega.nz/#!V8VS1Yib!p3MCZCzs8j7ruts2gAJtUPsJTflRIlTr8ZiXNKhTj1c

 

3- APP_Update_838-842.exe 5.1 MB      Password = Simple

https://mega.nz/#!49F3VAxS!t1w6Hq0fPubKxC-Zm7D8fjaULpUMhudqv-FXqfcE9es

 

4- APP_Update_842-846.rar 2.8 MB      Password = Simple

https://mega.nz/#!doFAAaKD!uTQ9QNW4-F6BBXUwom6vfeR6qtc1CTgvb5tHmGWlVK0

 

5- APP_Update_846-847.exe 6.6 MB

https://mega.nz/#!w4k0kCbC!gWQntkmuDk9J4LtDwy5f12nrapYP7t_yRWNx5M13TDs

 

If App-835 folder is used to update DiagBox 7.xx, then updates 2, 3, 4 and 5 can be used.

 

1- Download and execute the appropriate file for your own setup. The process will copy all necessary files to the updt folder, it will then automatically kill all associated processes to enable overwriting without conflicts.

2- Run DiagBox to start the update process and wait until DiagBox is operational. Once successfully operational, close DiagBox and restart your computer to ensure all processes are running.

 

Done..! you may run DiagBox as usual..

 

This should only be attempted if you already have updated APP folder (Lexia and PP2000) to 8.50, 8.53 or 8.54.

Ensure you have a backup copy of the file “C:\AWRoot\bin\fi\APPDIAG.SYS” before you start.

APP_Update_850-855.exe 135.1 MB Password = Simple

https://mega.nz/#!cksVCR4K!OAU_mFuv_5ZIGRbsdAcFLhvvcV7sS-f1n3_i_A09GeU

1- Download and execute the appropriate file for your own setup. The process will copy all necessary files to the updt folder, it will then automatically kill all DiagBox associated processes to enable overwriting without conflicts.
2- Run DiagBox to start the update process and wait until DiagBox is operational. Once successfully operational, close DiagBox and restart your computer to ensure all processes are running.

This update will change DiagBox version number to 07.855

 

DiagBox Software Update Procedures:

  • Ensure you have a backup copy of the file “C:\AWRoot\bin\fi\APPDIAG.SYS” before you start.
    2- Download and execute the appropriate file for your own setup. The process will copy all necessary files to the updt folder, it will then automatically kill all associated processes to enable overwriting without conflicts.
    3- Run DiagBox to start the update process and wait until DiagBox is operational. Close DiagBox and restart your computer to ensure all processes are running..! you may run DiagBox as usual.. Notice that DiagBox version will NOT be changed by these updates..Have fun!Lexia language is set to English and PP2000 to french, if you wish to change them, edit the DICO.TXT file in the EXE folders of LEXIA or OUTILREP (PP2000) and replace “GB” with “FR” or vise versa.

    P.S. DiagBox has been running on Firmware 4.3.4 since 7.66/8.02.

 

DiagBox Update Error:

Some readers follow the method above,but they get into trouble of DiagBox update error,please check below article to solve the error.

How to Solve DiagBox Update Error

auto

Recent Posts

JCB 3CX 4CX Backhoe Loader Engine Throttle Cable Removal and Replacement

JCB 3CX 4CX Backhoe Loader engine throttle cable is routed from the L.H. side of the…

2 days ago

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

3 weeks ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

3 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

4 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

1 month ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

1 month ago