To use Servicemaster connect your laptop computer to the machine CANbus. Connection is made using Data Link Adapter (DLA) C and the applicable cables.
Related Contents:
2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11
2017 JCB Parts Plus+ and Repair Service Manual Free Download
| A | USB PC Cable | 718/20235 |
| B | Serial PC Cable | 718/20236 |
| C | USB DLA | 728/26500 |
| D | Machine Cable | 718/20237 |
1 Make sure the machine ignition system is OFF.
2 Connect the ‘USB PC Cable’ A to the DLA and a free port on your laptop computer.
Note: Connect the USB cable directly to the laptop computer. DO NOT connect the cable via a USB hub.
Note: Older DLAs and laptop computers may not be compatible with USB ports. Use the serial PC cable B to connect the DLA to the laptop serial port.
3 Connect the ‘Machine Cable’ D to the DLA. The ‘Machine Cable’ has a 15-way D-type connector on one end and a 9-way CAN connector on the other.
Plug the 15-way connector into the DLA and tighten the thumb-screws.
4 Connect the 9-way CAN connector into the machines’ Diagnostics Connector A as follows: a Position the CAN connector B to align the centre pin location tab C with the diagnostics connector
A.
b Couple the connectors. Turn the locking ring D clockwise to secure the connectors
Yale G807 Brake System Air Bleed Guide Related Contents: 2023 Yale PC Service Tool…
This instruction show you guide on how to solve Bobcat G2 Stage V engine P000F…
Here is the instruction show you guide on how to solve CASE 7120 IH 20…
If the battery becomes discharged or does not have enough power to start the engine,…
Here is the instruction show you guide on how to solve Liebherr machine trouble code…
This instruction show you guide on how to solve AGCO machine trouble code SPN 1136…