This instruction show you guide on how to renew and adjust pneumatic actuator for Scania C,K series truck.
Related Contents:
2024.07 Scania SDP3 V2.61.2 V2.40 Diagnostic Software Free Download
2023 2018 Scania Multi EPC Parts Catalogue Free Download
Procedures:
Renewal – Pneumatic actuator, 9, 13 and 16 litre engines [XPI, gas]
Removing the pneumatic actuator
1.Unplug the connector for the EGR valve position sensor (3).
2.Detach the compressed air line from the actuator (2).
3.Undo the screws as illustrated (1).
Fitting the pneumatic actuator
1.Fit the actuator. Tighten the screws.
2.Attach the compressed air line to the actuator.
3.Plug in the connector for the EGR valve position sensor.
Adjusting – Pneumatic actuator, 9, 13 and 16 litre engines [XPI]
1.Apply basic settings to the actuator
2.Pre-load the actuator
3.Fit the nuts and washers.