This instruction show you guide on how to make Benz NTG 2.5 work/run on bench without car.It is very helpful to you when you need repair it.

 

What you need to do is connect NTG2.5 with your SDConnect C4,you need to connect KL30/KL31/CAN-H/CAN-L, you don’t need to connect the ignition pin because NTG2.5 doesn’t have KL15.

 

And, you need to attach a 120ohm resistor as a terminal between CAN-H and CAN-L, it’s a request of CAN BUS protocol. You can check this thread normal 0.125W-0.25W carbon resistor is OK(Wirewound is not OK)

Then, if your connection are all correct, you should use vediamo to code your NTG2.5, the CBF file is HU25. cbf, you can’t use Xentry/DAS because there is no ZGW on your bench, so the Xentry/DAS will never be connected with NTG2.5.

 

If you want to test rear view camera, you just need connect your camera to the NTG2.5, but you need supply +12V power to your camera manually.

auto

Recent Posts

How to Solve PowerCommand PCC2300 Fault Code 143 Low Oil Rifle Pressure

This instruction show you guide on how to to solve PowerCommand PCC2300 trouble code 143…

12 hours ago

How to Solve HINO J05E Engine P007B Intake Air Temperature Sensor Error

Here is the instruction show you guide on how to solve HINO J05E engine P007B…

3 days ago

AGCO EEM5 Stage V CORE 75-80 Supply Module

The supply module (SM) is a part of the vehicle SCR system. The SM is…

7 days ago

Yale G807 Brake System Air Bleed Guide

Yale G807 Brake System Air Bleed Guide   Related Contents: 2023 Yale PC Service Tool…

1 week ago

Bobcat G2 Stage V Engine P000F Common rail pressure Open Error Solution

This instruction show you guide on how to solve Bobcat G2 Stage V engine P000F…

2 weeks ago

How to Solve CASE 7120 IH 20 Series Axial-Flow Combine Creep Problem

Here is the instruction show you guide on how to solve CASE 7120 IH 20…

2 weeks ago