HINO 600 Series Truck P2048 DEF Injector Low Malfunction Repair

Here is a illustration show the guide on how to diagnostics and repair for HINO 600 series 15MY DCU Doser 500 malfunction of DEF injector low.

 

Preparations:

Nexiq USB2 Diagnostic Adapter

2024.03 HINO Diagnostic Explorer DX3/DX2 Diagnostic Software Free Download

HINO Trucks EPC Electronic Parts Catalog 2018 2016 Free Download

 

Procedures:

Step 1:Inspect for short-circuit in the DEF injector harness

Check the connection of the DEF injector connector (Looseness and poor contact).

Was any failure found?

Yes,connect securely,repair if needed.

Perform “After-inspection work” of INFORMATION section

No,go to step2

 

Step 2:Inspect the DEF injector unit

1.Set the starter switch to the “LOCK” position.

2.Disconnect the DEF injector connector.

3.Use the electrical tester to measure the resistance between the terminals of the DEF injector.

Measuring condition:starter switch lock

Measurement area:DEF injector DML-DMH

Standard value:20°C {68°F}:11.4 – 12.6Ω

Do the measurements meet the standard value?

Yes,go to step 3

No,replace the DEF injector.

Perform “After-inspection work” of INFORMATION section

 

Step 3:Inspect for short-circuit in the DEF injector harness

1.Disconnect the DCU 86P connector.

2.Connect the signal check harness and use the electrical tester to measure the resistance between the terminals of the DCU 86P vehicle-side connector and the ground.

Measuring condition:Starter switch: LOCK

Measurement area:DCU 86Pvehicle-side connector,DML- Ground,DMH- Ground

Standard value:∞Ω

Do the measurements meet the standard value?

Yes,go to step4

No,repair or replace the harness.

Perform “After-inspection work” of INFORMATION section

 

Step 4:Inspect disconnection of the DEF injector harness

1.Connect the DEF injector connector.

2.Connect the signal check harness and use the electrical tester to measure the resistance between the terminals of the DCU 86P vehicle-side connector.

Measuring condition:Starter switch: LOCK

Measurement area:DCU 86P vehicle-side connector,DML,DMH

Standard value:20°C {68°F}:11.4 – 12.6Ω

Do the measurements meet the standard value?

Yes,go to step5

No,repair or replace the harness.

Perform “After-inspection work” of INFORMATION section

 

Step 5:Check the DTG detected (DCU)

1.Perform an engine warm-up. (Water temperature: 60 °C {140 °F} or more)

2.Stop the engine and set the starter switch to the “LOCK” position.

3.Connect the vehicle to HINO DXⅡ

4.Set the starter switch to the “ON” position.

5.Select [DCU] and check if P2048 has been detected.

Has DTC P2048 detected?

Yes,replace the DCU (Perform DPR forced regeneration after replacement)

Perform “After-inspection work” of INFORMATION section

 

No,procedure completed

Perform “After-inspection work” of INFORMATION section

 

More case for HINO please refer to:HINO Trouble Repair.

auto

Recent Posts

How to Write Engine and Machine ID into ECU for Doosan DL06

After ECU reparogramming,it is necessary to write new engine number and machine ID into ECU.So…

5 hours ago

PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution

PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution   Related Contents: 2024 InPower V14.5…

1 day ago

Volvo 2017 Engine Emissions ACM P054415 Exhaust Gas Sensor Error

The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…

5 days ago

How to Use MTU DiaSys Diagnostic Software to Connect MTU Engine

MTU DiaSys diagnostic software is professional on MTU engine diagnostics and programming.But seems that is…

1 week ago

Cummings ISX 12 and 15L EPA7 Engine Aftertreatment Injector Flow Test by JPRO

This instruction show you guide on how to use JPRO Diagnostic to do aftertreatment injector…

1 week ago

How to Setup Diagnostic Vendor Adapter for Hyster Yale PC Service Tool

There are several different diagnostic vendor adapter support Hyster and Yale forklift truck,here show you…

1 week ago