Here is the instruction show yo guide on how to solve Fendt MT800E tractor DEF tank temperature does not change during the heating cycle.
Preparations:
Code SA 00 SPN 3031 FMI 10
The DEF tank temperature does not change during the heating cycle.
Diagnosis and solution
Clear the error log.
Restart the engine module.
If the fault code shows again during the next driving cycle, check the following.
Check the coolant supply of the tank heating element.
Install a new DEF tank heating valve to see if the original is bad.
Check the DEF tank temperature sensor harness. Make sure the connections are good and the contacts are clean.
Replace the DEF tank temperature sensor. If the system is correct and the fault code is not active, the original sensor is bad.
If you want more repair cases for Fendt tractor,please refer to Fendt Tractor Trouble Repair
It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…
Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…
This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…
Here is the instruction show you guide on how to install the left-hand drum bearing…
This instruction show you guide on how to remove and replace loader lift ram for…
This instruction show you guide on how to solve Caterpillar C9 engine 31 84-1 fault…