Doosan equipment machine relief pressure check guide,it must be performed for VBO calibration.
Preparations:
Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Relief pressure check
*Calibration judgement
5.1. Measure the input & output voltage of main pump pressure sensor
5.1.1. Check the output voltage when it is connected under unloaded condition.
5.1.2. Check the output voltage of the pilot pressure sensor while the machine is in operation.
(Take the DMS-5 monitoring data during the test)
5.1.3. Check if the voltage value measured at the pressure sensor is matched with the pressure indicated on the gauge panel.
5.1.4. Operate the machine and check if the pressure value indicated on the gauge panel is changed according to changes in the pressure.
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
*Operating voltage: 5V ± 5%, Output voltage: 1 ~ 5V, Operating current: max. 10 mA, measuring pressure: 0 to 500 bar, Measurement tolerance: ±5%
*Formula for voltage-pressure conversion: Voltage = (0.00816 x Pressure) + 1
5.2. Check the physical condition of the main pump pressure sensor
5.2.1. Assembly condition
5.2.2. External damage
5.2.3. Short circuit
Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)
5.3. Check the physical condition of the main relief valve on MCV
5.3.1. Assembly condition
5.3.2. Internal blockage
More topics for Doosan,please refer to:Doosan Trouble Repair
This instruction show you guide on how to replace engine rotation speed sensor crankshaft for…
This post show you guide on how to install evaporator for CLAAS Lexion 480 combine.…
This instruction show you guide on how to solve Bobcat engine DCU P1A32 Self-Diagnostis in…
How to Use Hyster Yale PC Service Tool Password Management Function Note: To access…
When you use IDSS diagnostic scan to do some function,it may occur communication error.Sometime you…
Deutz engine EOL test (end of line) is required to ensure the EAT functionality. Conditions…