Detroit Diesel GHG14 DDEC VI Engine Regeneration Troubleshooting

This is an instruction show you guide on how to do regeneration troubleshooting for Detroit Diesel GHG14 DDEC VI engine.

 

Related Contents:

2024 Detroit Diesel Diagnostic Link DDDL 8.19 8.09 Free Download

JPRO DLA+ 2.0 Adapter

NEXIQ USB Link Adapter

 

 

Procedures:

Note : This diagnostic should be completed first for regeneration issues.

Verification: Verify Parked Regeneration Completes

1.Connect using DiagnosticLink ®  and then turn the ignition ON (key ON, engine OFF).

2.Using DiagnosticLink, check for fault codes. Are any Fuel System or Air System fault codes present?

2a Yes; troubleshoot those codes first.

2b No; Go to step 3.

 

WARNING  

HOT EXHAUST

During parked regeneration the exhaust gases will be extremely HOT and could cause a fire if directed at combustible materials. The vehicle must be parked outside.

 

Note : If the unit is in zone zero, the system will not initiate a parked regeneration without using DiagnosticLink.

 

3.Using DiagnosticLink, go to Service Routines/DPF System/Perform Parked Regeneration/Start. Does the regeneration start successfully by reaching at least 1,100 rpm?

3a Yes; let the regeneration continue to run and Go to step 4.

3b No; Regeneration – Unable to Start a Parked Regeneration

 

4.Does the regeneration end at any time without a fault code coming active?

4a Yes; Regeneration – Regeneration Ends Abruptly.

4b No; Go to step 5.

 

5.Using DiagnosticLink, monitor DOC inlet temperature. Does the DOC inlet temperature reach 280 °C (536 °F)?

5a Yes; Go to step 6.

5b No; Regeneration – DOC Inlet Temperature Unable to Reach HC Dosing Temperature .

 

6.Using the chart tab in DiagnosticLink, monitor DOC outlet temp and DOC Out Model Delay. After 30 minutes into the regeneration, is there a difference greater than +/- 55.5°C (100°F)?

6a Yes; Regeneration – DOC Outlet Temperature Unable to Meet Model Delay .

6b No; Go to step 7.

 

7.Using the chart tab in DiagnosticLink, monitor AS077: Fuel Cut Off Valve. At 30 minutes, does Fuel Cut Off Valve stay steady at 100%?

7a Yes; troubleshooting is complete.

7b No; stop the parked regen and start a DOC Face Cleaning service routine, found under Action – Aftertreatment. Let the routine run for one minute, then stop it. Start another parked regen and verify it completes successfully.

 

More repair cases for Detroit Diesel engines,please refer to:Detroit Diesel Engine Repair

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

1 week ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

2 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago