ZF-ASTRONIC Transmission Bleeding Guide

This illustration show you guide on how to perform bleeding for ZF-ASTRONIC transmission.

 

Related Contents:

ZF Testman Pro 10.5 Transmission Diagnostic Software Free Download

 

The transmission is fitted with a vent on the transmission actuator as standard. The vent should be protected from the ingress of large amounts of water. The vent must be clean; ensure that the
plastic cover is not fitted.
In the case of vehicles which are frequently cleaned with a water jet, moisture or moist air may be
drawn into the vent as a result of sudden transmission cooling, causing condensation to form inside the transmission. Also applications where the transmission is located in the water-expelling area of the rear wheels may be affected by this.

 

Since the proportion of water in the transmission oil must not exceed 1000 ppm, ZF recommends that rather than the standard vent, a hose-type vent be installed in the vehicle’s dry compartment. The transmission’s interface to the hose may be supplied having been fitted in the factory.
A retrofit kit for hose venting is available under ZF number 1315 298 021 from ZF Service.

This provides the best-possible protection for the transmission against water ingress. When using
this form of hose venting, the oil change interval for ECOFLUID M transmission oil increases.

 

Notes on the “dry compartment” and routing of the hose:
“Dry compartment” is defined as follows:
• Splash-protected
• Low air humidity
Example: trunk, battery compartment

 

The following should be noted when fitting the hose (also refer to sketch):
• Ensure that the hose exits the transmission vent horizontally (use angle screw connection if necessary).
• Route hose so that it rises continuously. A siphon effect should be avoided (see sketch).
• No kinks, chafing points. Route hose in the largest radius possible.
• Max. permissible hose temperature (e.g. near exhaust pipes, exhaust turbocharger) must not be exceeded.
• End of hose lowered by approx. 150 mm.
• Inside width of hose should be at least Ø 4 mm.
• The vehicle manufacturer is responsible for the correct fitting and routing of the hose.

Fig: Guideline for routing a hose-typevent to the dry compartment

auto

Recent Posts

How to Solve Bobcat Engine DCU P1A32 Fault Code

This instruction show you guide on how to solve Bobcat engine DCU P1A32 Self-Diagnostis in…

54 mins ago

How to Use Hyster Yale PC Service Tool Password Management Function?

How to Use Hyster Yale PC Service Tool Password Management Function   Note: To access…

1 day ago

How to Solve ISUZU IDSS Diagnostic Adapter Does Not Communicate with CAN Device

When you use IDSS diagnostic scan to do some function,it may occur communication error.Sometime you…

2 days ago

How to Perform EOL Test for Deutz Tier4F Engine

Deutz engine  EOL test (end of line) is required to ensure the EAT functionality. Conditions…

3 days ago

Scania Articulation Control System ACS 10 End Position Sensor Error

This instruction show you guide on how to solve Scania truck articulation control system ACS…

4 days ago

Magneti Marelli 49FB – Fiat ECU Pinout

Magneti Marelli 49FB – Fiat ECU Pinout   More ECU PINOUT Components: ECU Modules Repair…

1 week ago