PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution
Related Contents:
2024 InPower V14.5 Pro V12 Diagnostic Software Free Download
PowerCommand Diagnostic 9 Pin Adapter Cable for InPower
Logic:
This fault is used when an optional coolant level sensor is installed. The nature of the fault is an optional customer selection.
The fault function can be programmed (using the InPower service tool), as follows:
• Enable/disable input (Default: enable)
• Status, Warning, or Shutdown (Default: #1-None, #2 and #3-Warning)
• Active closed or open (Default: closed [ground])
• Change the display name using up to 19 characters (Default: #1- Customer Fault 1, #2-Ground Fault, #3-Low Fuel)
Possible Cause:
1 Low coolant
2 No actual fault, external wiring problem
Diagnosis and Repair:
1 Low coolant
a If the generator set is powering critical loads and cannot be shut down, wait until next shutdown period, then do the steps that follow.
b Allow engine to completely.
c Check coolant level and replenish if low.
2 No actual fault, external wiring problem
a Disconnect the signal lead from TB1 and reset the control.
a CONFIG INPUT 1 – TB1-13
b If the message goes away, the external wiring has a short circuit. Grounding of either input activates fault.
Here show you guide on how to solve Doosan machine Timeout error of CAN receive…
This instruction show you guide on how to solve Liebherr machine emergency stop ignition on…
This instruction show you guide on how to solve Doosan machine trouble code U043D message…
Here is the instruction show you guide on how to solve AGCO machine trouble code…
Detroit DD13 EPA10 (2010-13) trouble code SPN 84 FMI 13 (MCM) J1939 Wheel-based vehicle speed…
This instruction show you guide on how to solve Caterpillar C9 engine trouble code 36…