Kubota U48-4 U55-4 Refrigerant Pressure Switch Test Check

Here is an instruction show you guide how to check and test refrigerant pressure switch for Kubota U48-4 and U55-4 excavator.

 

Preparations:

2022 Kubota Takeuchi Diagmaster v22.08.01 v4.1.2 Software Free Download
Kubota DST-i Diagnostic Adapter

Kubota EPC Spare Parts Catalogue 2021.06 Download

 

Procedures:

When a pressure switch (inside the high-pressure/low-pressure switch) is operating normally, electricity is conducted (ON) and when an abnormal pressure occurs, it trips the switch, blocking the electricity (OFF).

Manifold gauge connections
1 Close the HI (high-pressure side) valve (3) and the LO (low-pressure side) valve (2) of the manifold gauge (1) securely.
2 Connect the red charging hose (4) to the HI (high-pressure side) charge valve (1) and the blue charging hose (5) to the LO (low-pressure side) charge valve (2).
3 Open the manifold gauge’s HI (high-pressure side) valve (3) a little and press on the valve core to expel any air inside its charging hose (4). Then close the HI (high-pressure side) valve (3) tightly.

4 Open the manifold gauge’s LO (low-pressure side) valve (2) a little and press on the valve core to expel any air inside its charging hose (5). Then close the LO (low-pressure side) valve (2) tightly.

(1) Manifold gauge
(2) Low-pressure valve
(3) High-pressure valve
(4) Red charging hose
(5) Blue charging hose

 

When refrigerant pressure is rising (OFF)
1Start the engine and set it at 1,500 rpms. Turn the AC switch on the control panel on, set the fan switch to HI and set the temperature control lever to the max cool position.
2 Cover the front of the condenser with cardboard or the like and raise the pressure on the high pressure side of the AC cycle.

3 Once the pressure on the high-pressure side rises, the high-pressure switch operates, turning the magnetic clutch of the compressor off. When it does so, read the HI (high-pressure) gauge of the manifold gauge and if it reads higher than the pressure setting, replace the pressure switch
(8).
• Pressure setting on the high-pressure side of the switch:
Switches off at approximately 3.14 MPa (32 kgf/cm2, 460 psi) or higher

When refrigerant pressure is dropping (OFF)
1Remove the connector of the pressure switch (8).
2Measure the resistance between the terminals of the pressure switch with a circuit tester. It should register 0Ω unless there is insufficient gas due to a leak or unless the pressure switch is faulty.
• Pressure setting on the low-pressure side of the switch:
Switches off at approximately 0.196 MPa (2.0 kgf/cm2, 28 psi)

More repair case for Kubota,please refer to:Kubota Trouble Repair

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

1 week ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

2 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago