Komatsu PC130 Excavator Attachment Flow Adjustment Guide

This instruction show you guide on how to adjust attachment flow for Komatsu PC130 excavator.This instruction can adjust various items related to the machine with the machine monitor.The function of “Attachment Flow Adjustment” is used to finely adjust the oil flow to the attachment in compound operation.All workshop manual and part catalogue you can refer to:Komatsu CSS Full Set 2018 2014 Parts Viwer Free Download

 

Procedures:

Selecting menu
Select “Adjustment” on the “Service Menu” screen.

 

Selecting sub menu
After the “Adjustment” screen is displayed,select “Attachment Flow Adjustment” with the function switches or numeral input switches.
Select this item similarly to an item on the “Service Menu” screen.

Selecting distribution of oil flow
After the screen of “Attachment Flow Adjustment” is displayed, select a set value on the right side with the function switches.
Set value: For actual distribution of flow,see table
-[F3]: Increase set value
-[F4]: Decrease set value
-[F6]: Confirm setting and return to Adjustment menu screen
-The 3 digits on the left side do not vary since they are the code of this function.

Relationship between set value and distribution of flow to attachment

More about Komatsu repair,please visit here:Komatsu Excavator Repair.

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

2 weeks ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

3 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

3 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

1 month ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

1 month ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

1 month ago