This instruction show you guide on how to solve JCB Isuzu 6HK1 INT-Tier4 engine DTC U0110 Flash Code 87 lost communication with VNT system error.
Preparations:
ISUZU E-IDSS 2024 2019 Engine Diagnostic Service System Free Download
Procedures:
U0110 Diagnostics
1 Turn OFF the ignition switch.
2 Remove the harness connector from the turbo control unit.
3 Measure the voltage between the ISO CAN-Low circuit and GND of the turbo control unit harness connector.
4 Measure the voltage between the ISO CAN-High circuit and GND of the turbo control unit harness connector.
Voltage:1.5 to 3.5 V
5 If the reading is outside the specified range, inspect to see if there is an open circuit or high resistance with the ISO CAN-High circuit between the turbo control unit and the ECM.
6 If a problem is found, repair the ISO CAN-High circuit.
7 Inspect to see if there is an open circuit or high resistance with the ISO CAN-Low circuit between the turbo control unit and the ECM.
8 If a problem is found, repair the ISO CAN-Low circuit.
9 Inspect the turbo control unit harness connector for a poor connection.
10 If a problem is found, repair the harness connector.
11 Replace the turbocharger assembly.
U0110 Confirm Resolution
1 Clear the DTC using the trouble diagnosis scan tool.
2 Turn OFF the ignition switch for at least 30 seconds.
3 Start the engine.
4 Perform a test-run.
5 Use the trouble diagnosis scan tool to confirm that a DTC has not been detected.
More repair cases for ISUZU engine,please refer to:ISUZU Engine Trouble Repair
Here is the instruction show you guide on how to replace fuel tank breather filter…
FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…
Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…
This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…
This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…
This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…