This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 / EGRCD_SigNpl error.
Error description EGR ACTUATOR
Actuator of the external EGR valve: the ECU detects no load or excess temperature of the ECU component for power supply of the connected components.
Related Contents:
2023 Deutz Serdia 4.0 Serdia 2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Serpic EPC Parts Catalogue 2014 2012 Free Download
Error codes
DEUTZ-Errorcode: 71
BlinkCode (short-long-short): 4 – 1 – 5
SPN: 2791
Possible FMI:
5: current to low or broken wire
2: data stream is defective
Error Detection
Errorlamp shows permanent light. Entry in errormemory.
Possible reason for error
Cable break or excess temperature, sensor defective, connection cable demaged
Take actions for error repair
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Other error properties
System reaction: Warning, shutoff output, power reduction via second topcurve?
Behaviour error lamp: permanent light
Selfhealing: no
Signal Priority: 3
Measurement @ errortime: shut off value
For more topics about Deutz repair case,please refer to:Deutz Trouble Repair.
Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…
This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…
This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…
This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…
Here is the instruction show you guide on how to solve Scania Truck ATA 152…
This instruction show you guide on how to solve Valtra BH Series 140-210 trouble code SA…