This instruction show you guide on how to solve Bobcat engine DCU P1A32 Self-Diagnostis in NOx sensor 2 downstream.

 

Related Contents:

Bobcat Engine Analyzer ECU DCU 2023

2023 Bobcat Service Analyzer 91.15 91.05 Diagnostic Free Download

 

Overview:

U005713-02

1Electric problem (NOx sensor connector, Wiring harness NOx sensor controller to sensing part, NOx sensor)
2 Electric problem (CAN wiring harness insulation, Resistance)

 

Component Location:

 

3) Condition for Running Diagnostic
Non-continuous diagnosis in post-drive
4) Condition for Setting the Fault Code
The average of relative sensor NOx curve slope read from the sensor is outside the tolerance band and
the debouncing has expired the limits (Between 50% and 150%)
5) Condition for Clearing the Fault Code
The average of relative sensor NOx curve slopes read from the sensor is inside the tolerance band and
the debouncing has expired the limits (Between 50% and 150%)

 

6) Check List

Step 1:

P1A32 is occurred on diagnostic tool?

Yes,go to step 2

 

Step 2:

After let the machine be in safety area and turn
off the key switch

Yes,go to step 3

 

Step 3:

Check DCU connection connection problem?

Yes,no necessary repair

No,go to step 4

 

Step 4:

Check sensor connection Connection problem?

Yes,No necessary repair

No,go to step5

Step 5:

Check Network (CAN line, resistance of H/L) Network problem?

Yes,no necessary

No,go to step 6

 

Step 6:

Check continuity and electrical insulation Electrical problem?

Yes,fix harness

No,change sensor.

 

 

2023 Bobcat Engine Analyzer ECU DCU Diagnostic Software

auto

Recent Posts

Doosan Bobcat Machine Electric Fault Troubleshooting Guide Tip

This instruction show you guide on how to solve Doosan and Bobcat Electric problems can…

23 hours ago

How to Download and Install JCB DLA 2.0 Driver?

It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…

7 days ago

How to Solve Deutz EMR3 Engine 94 /523239/FrmMngDecV1?

Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…

1 week ago

How to Solve AGCO Machine Trouble Urea pressure too high?

This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…

2 weeks ago

How to Install Left-hand Drum Bearing Assembly for CLAAS LEXION 480

Here is the instruction show you guide on how to install the left-hand drum bearing…

3 weeks ago

How to Remove and Replace Loader Lift Ram for JCB 3CX 4CX Machine

This instruction show you guide on how to remove and replace loader lift ram for…

4 weeks ago