Procedures:

1 Remove the hoses under center joint (1).

2 Remove bolts (2) (4 used) and washers (3) (4 used).

Remove cover (1).

 

3 Remove bolts (1) (6 used) and washers (2) (6 used).

Remove cover (3).

j : 22 mm

4 Remove bolts, washers (4) (4 used) and clamps (5) (2 used).

j : 17 mm

5 Disconnect the both ends of pipes (6) (24 used).

j : 17 mm

 

 

CAUTION: Upperstructure (1) weight: 50100 kg

(110500 lb)

IMPORTANT: Install a soft rubber onto the wire rope contacting surface in order not to damage the main frame.

 

6 Install shackles (2 used) to lifting holes (a) (2 places).

Attach nylon slings onto the shackles (2 used).

Attach wire ropes onto counterweight mounting parts (b) (2 places). Hoist and hold upperstructure

(1) by using nylon slings and wire ropes.

 

7 Put the matching marks on upperstructure (1) and undercarriage (2). Remove bolts (3) (62 used) and washers (4) (62 used). Remove upperstructure (1) from undercarriage (2). Place upperstructure (1) onto wooden blocks.

 

More repair case for Hitachi,please refer to Hitachi excavator trouble repair

auto

Recent Posts

How to Solve Liebherr Machine Power or Speed Reduction?

How to solve Liebherr machine trouble code P1188 power or speed reduction emission related failure.…

6 days ago

Doosan Machine Timeout Error of CAN Receive Frame AUXIO1

Here show you guide on how to solve Doosan machine Timeout error of CAN receive…

2 weeks ago

Liebherr Machine Emergency Stop-Ignition on While Emergency Stop is Active

This instruction show you guide on how to solve Liebherr machine emergency stop ignition on…

3 weeks ago

How to Solve Doosan Machine U043D CAN Receive Frame Counter Error

This instruction show you guide on how to solve Doosan machine trouble code U043D message…

4 weeks ago

AGCO Machine Trouble Code SPN 1485 – FMI 03 Solution

Here is the instruction show you guide on how to solve AGCO machine trouble code…

1 month ago

Detroit DD13 J1939 Wheel-Based Vehicle Speed Sensor Signal Missing

Detroit DD13 EPA10 (2010-13) trouble code SPN 84 FMI 13 (MCM) J1939 Wheel-based vehicle speed…

2 months ago