Cat ET Intake Valve Actuator Test manual mode allows troubleshooting a specific intake valve actuator. This is done by energizing an individual intake valve actuator. All intake valve actuators are deenergized at the start of the test, and only one actuator may be energized at a time.

Related Contents:

Caterpillar ET 2024A 2023A 2018A Electronic Technician Software Free Download

CAT Communication Adapter 3 478-0235

Caterpillar Factory 18 Digits Password Service

 

 

To start the automated test:

1 Click the Start button. The Select Intake Valve Actuator Test screen is displayed.

2 Click the Manual Intake Valve Actuator Test radio button, and then click Continue>>. The Intake Valve Actuator Test Conditions screen is displayed.

3 When the service conditions are met, click Continue>> to begin the test.

Note: The Test will not run unless all test conditions are met. If service conditions are not met, the Intake Valve Actuator Test Aborted screen is displayed, noting the reason(s) the test was stopped. Click <<Back to return to the Intake Valve Actuator Test screen.

4 If test conditions are met, a warning box displays the following message:

Running this test will cause significant engine smoke.

This test should be run in a well-ventilated area.

Click OK to continue the test, or click Stop to abort the test and return to the Intake Valve Actuator Test main screen.

 

5 A WARNING message box may be displayed if:

If the cooling fan is controlled by the ECM. Click OK to continue the test, or click Stop to abort the test without turning on the cooling fan.

If the engine speed is controlled by the ECM. Click OK to continue the test. The Intake Valve Actuator Test main screen will be displayed in automated test mode. Click Stop to abort the test without adjusting engine speed.

 

Note: Clicking Stop causes the shutdown process to begin. During this process, the engine speed automatically increases, and a progress bar displays the completion status of the increase. Then, as the increased engine speed is maintained for a specific amount of time, the progress bar displays the progress of the maintained increased engine speed. The Test Stopped by User message box displays post-test instructions.

 

6 To troubleshoot a specific intake valve actuator, double-click the actuator to be tested, or highlight it and click the Change button. This will energize the intake valve actuator to be tested.

 

Note: The selected intake valve actuator will stay energized for five seconds only, and then the service tool will return the state to de-energized. Only one actuator can be energized at a time.

 

Note: The intake valve actuators can be tested a limited number of times. When this limit has been reached, a message box will be displayed. Click OK. To continue testing, the Intake Valve Actuator Test must be exited.

7 Click Stop to end the Intake Valve Actuator Test in manual mode.

CAT ET 2024A

auto

Recent Posts

Bobcat G2 Stage V Engine P000F Common rail pressure Open Error Solution

This instruction show you guide on how to solve Bobcat G2 Stage V engine P000F…

1 day ago

How to Solve CASE 7120 IH 20 Series Axial-Flow Combine Creep Problem

Here is the instruction show you guide on how to solve CASE 7120 IH 20…

4 days ago

How to Jump-start Engine for MANITOU MT6034 Construction Telehandler

If the battery becomes discharged or does not have enough power to start the engine,…

1 week ago

Liebherr Machine P1121 DEF Pump Out of Service Error Solution

Here is the instruction show you guide on how to solve Liebherr machine trouble code…

1 week ago

AGCO Machine Trouble Code SPN 1136 ECU Temperature NO SIGNAL

This instruction show you guide on how to solve AGCO machine trouble code SPN 1136…

2 weeks ago

How to Solve JCB JS140/205/215 Machine P2280-00 Air Filter Blocked

This instruction show guide on how to solve JCB JS140/205/215 machine trouble code P2280-00 air…

2 weeks ago