How to Configure Chassis Angle Sensor for JCB 3CX/4CX/5CX

The procedure outlined below describes how to configure a replacement chassis angle sensor (728/E2897) on the JCB Pilemaster machine. This process does not require any additional tooling or diagnostics equipment and is carried out through the rear display service menu.

 

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.6.2 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

Chassis Angle Sensor Configuration Procedure

Accessing the Rear Display Service Menu

1 Ensure the machine’s ignition is turned OFF.

2 Disconnect the mast angle sensor. The position of the mast angle sensor is shown below.

 

3 Ensure that all of the emergency stop buttons are ‘out’ and have not been pressed.

4 Turn the machine’s ignition ON.

5 Ensure the rear display is ON and wait for the drill information screen to show.

Note: if the rear display does not switch ON, re-check the emergency stop buttons.

6 Press and hold both the F1 and F2 buttons. Wait 5 seconds and then press the OK button whilst still holding down the F1 and F2 buttons.

7 The display should now show the service menu.

8 The menu items are selectable by pressing the UP and DOWN arrows.

9 To access an option, press the OK button.

10 To exit the menu, select “exit” and press the OK button.

 

Chassis Angle Sensor Configuration

1 Select “angle sensor configuration” and press the OK button.

2 A confirmation screen will show stating that the mast angle sensor must be disconnected before continuing.

3 If the mast angle sensor has been disconnected, press the F2 button and the chassis angle sensor will be configured. Pressing the F3 button will abort the process.

4 Once the sensor has been configured (or aborted), the display will return to the service menu screen.

5 Exit the service menu screen and turn the machine’s ignition OFF.

6 Re-connect the mast angle sensor.

 

Checking the Angle Sensors Operation

1 Turn the machine’s ignition ON and start the engine.

2 Change the display from the drill information screen to the angle information screen by pressing the UP or DOWN button.

3 Extend the stabiliser legs to full extension. The upper two segments will react to the changes in angles from the chassis angle sensor.

4 Move the boom up and down. The lower two segments will react to the changes in angles from the mast angle sensor.

5 Once the angle sensors have been confirmed as operating, return the drill end to the ‘travel’ position and retract the stabiliser legs fully.

6 Turn the engine OFF.

More repair case for JCB,please refer to:JCB Trouble Repair

 

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

1 week ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

2 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago