Eaton Heavy Duty Transmission TRSM1500 Shift Bar Housing Installation Guide

This instruction show the guide on how to install shift bar housing for Eaton heavy duty transmission TRSM1500.There are three (3) sizes of Cap Screws. The 1 1/2″ Cap Screws are used with the Lifting Eyes. The 1 1/4″ are used on all other locations except the left front corner at the Roll Pin. This Cap Screw is 1 3/4″.

 

Be careful when removing the Shift Bar Housing to prevent damaging the Oil Tube with the Shift Yokes. The Slave Valve and Interlock parts must be removed prior to installing the Shift Bar Housing.

 

2022 EATON ServiceRanger 4.10 and 4.2 + Activator Free Download

 

Procedure

1.Place the Shift Bar Housing and Shift Blocks in the  Neutral position.

2.Place the Mainshaft Sliding Clutches in the Neutral position.

3.Position a new Shift Bar Housing gasket on the Shift Bar Housing mounting surface.

Note: The Slave Valve and Interlock Assembly must remain  off, until the Shift Bar Housing is installed, to avoid damaging the Interlock Pin.

4.As you install the Shift Bar Housing, make sure the Yokes fit into the corresponding Sliding Clutch slots and the Housing aligns with the Roll Pin.

5.Apply Eaton® Sealant #71205 or equivalent to the Retaining Cap Screws. Torque the Cap Screws to 35–45 lb-ft (47.45–61.01 N•m).

6.Install Interlock parts (Pin, Spring and Sleeve).

7.Install Slave Valve. Apply Loctite 242 to Cap Screw threads and torque to 8–12 lb-ft (10.85–16.30 N•m).

auto

Recent Posts

AGCO EEM5 Stage V CORE 75-80 Supply Module

The supply module (SM) is a part of the vehicle SCR system. The SM is…

14 hours ago

Yale G807 Brake System Air Bleed Guide

Yale G807 Brake System Air Bleed Guide   Related Contents: 2023 Yale PC Service Tool…

4 days ago

Bobcat G2 Stage V Engine P000F Common rail pressure Open Error Solution

This instruction show you guide on how to solve Bobcat G2 Stage V engine P000F…

7 days ago

How to Solve CASE 7120 IH 20 Series Axial-Flow Combine Creep Problem

Here is the instruction show you guide on how to solve CASE 7120 IH 20…

1 week ago

How to Jump-start Engine for MANITOU MT6034 Construction Telehandler

If the battery becomes discharged or does not have enough power to start the engine,…

2 weeks ago

Liebherr Machine P1121 DEF Pump Out of Service Error Solution

Here is the instruction show you guide on how to solve Liebherr machine trouble code…

2 weeks ago