This instruction show you guide on how to do angle sensor check for Doosan machine.

 

Preparations:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Doosan Diagnostic Tool

 

Procedures:

Angle sensor check

*Calibration judgement

Depends on the model type. The criteria referred on DMS-5

 

2.1. Measure the input & output voltage of angle sensor in certain condition

Ex. DX350LC-7, outputs of angle sensor (Please refer the shop manual to check the exact value on each model)

  1. -45°: 0.5 V ±0.025V
  2. 0° : 2.5 V ±0.05V
  3. 45° : 4.5 V ±0.025V

*Operating voltage: 24V ±10%, Output voltage: 0.5V ~ 4.5V

 

2.2. Check the physical condition of angle sensor

2.2.1. Assembly condition

Contact type (ex. DX350LC-7)

1) Ensure that ball pin is guided in the nut of the spring collar in spring position. (Install the angle sensor with the electrical connection to the top.)

2) Center (rotate) the shaft of the swivel angle sensor between the stoppers like the position on the Figure

3) Check the groove/slot position of the sensor shaft in the controller (must not be horizontal) and set (rotate) and install the swivel angle sensor to groove/slot position.

4) Turn the angle sensor to adjust the signal of +4.5 V at the Q-max position of the rotary group and install the screw with the correct torque.

Non-contact type (ex. DX800LC-5B)

2.2.2. External damage

2.2.3. Short circuit

Ex. DX350LC-7(Please refer the shop manual to check the exact value on each model)

More topics for Doosan,please refer to:Doosan Trouble Repair

auto

Recent Posts

Liebherr Machine Emergency Stop-Ignition on While Emergency Stop is Active

This instruction show you guide on how to solve Liebherr machine emergency stop ignition on…

7 days ago

How to Solve Doosan Machine U043D CAN Receive Frame Counter Error

This instruction show you guide on how to solve Doosan machine trouble code U043D message…

2 weeks ago

AGCO Machine Trouble Code SPN 1485 – FMI 03 Solution

Here is the instruction show you guide on how to solve AGCO machine trouble code…

3 weeks ago

Detroit DD13 J1939 Wheel-Based Vehicle Speed Sensor Signal Missing

Detroit DD13 EPA10 (2010-13) trouble code SPN 84 FMI 13 (MCM) J1939 Wheel-based vehicle speed…

1 month ago

How to Solve Caterpillar C9 Vehicle Speed Signal Invalid?

This instruction show you guide on how to solve Caterpillar C9 engine trouble code 36…

1 month ago

Kubota L3301 L3901 Excavator Safety Valve Setting Pressure Test

Kubota L3301 L3901 Excavator Safety Valve Setting Pressure Test Using Injection Nozzle Tester 1 Remove…

1 month ago