Benz E211 Central Gateway Offline Coding by DAS Xentry

This article show you procedures on DAS Xentry perform Central Gateway offline coding for Mercedes Benz E211.And i wrote Benz module coding projects here:Benz coding,check it to get more tests.

 

Preparations:

Benz DTS Monaco Software Free Download

How to Install Mercedes Benz DTS Monaco Software

VXDIAG Benz/BMW

 

Central Gateway Offline Coding by DAS Xentry:

Run Benz DAS Xentry diagnosis software

After vehicle identification and data reading,select “Quick Test”,then click “F3”

Wait for all modules data determined…

 

Note:It was not possible to automatically read all the values and they must therefore be entered manually.

 

After all control units quick test finish,select “CGW-Central gateway”and click “F3” button to continue

Select “Control unit adaptations”,then click “F3” button

Select “Control module programming”,F3 to continue

In the following procedure,the data of the following modules is programmed in full:

-Central gateway

-System diagnosis

-ASSYST

-ASSYST PLUS

Note:Sufficient voltage must be available throughout the procedure.

Click “F2”

Select “Offline (diagnostic unit not networked)”,click “F3” to continue

The measures to be performed on the vehicle can be supported using the online network connection to the central system or offline.

The “online” process is always recommended.

This ensures that the diagnostic system operates with the current data.

If a network connection is not available,the “offline” process can be used

Data record selection Control module programming

New control unit software versions are available for the following control units:

Control unit Central gateway Estimated programming duration:2 Minutes

Perform control unit programming?

Click “Yes” to continue

Enter the reason for control unit programming:up

Click “F2” to continue

The coding is being read,please wait…

It will reset control unit to original delivery status

Rest of control module is performed.

Control unit Central gateway programming progress,it will take about 2 minutes

Check the notes:

 

The coding is being carried out,please wait

Erase fault memory,please switch on ignition

Central Gateway programming was completed successfully

All input fields must be filled out,then click “F2” to continue

Done!

auto

Recent Posts

PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution

PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution   Related Contents: 2024 InPower V14.5…

1 day ago

Volvo 2017 Engine Emissions ACM P054415 Exhaust Gas Sensor Error

The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…

5 days ago

How to Use MTU DiaSys Diagnostic Software to Connect MTU Engine

MTU DiaSys diagnostic software is professional on MTU engine diagnostics and programming.But seems that is…

1 week ago

Cummings ISX 12 and 15L EPA7 Engine Aftertreatment Injector Flow Test by JPRO

This instruction show you guide on how to use JPRO Diagnostic to do aftertreatment injector…

1 week ago

How to Setup Diagnostic Vendor Adapter for Hyster Yale PC Service Tool

There are several different diagnostic vendor adapter support Hyster and Yale forklift truck,here show you…

1 week ago

How to Use Deutz SerDia2010 SCR End Of Line Function

For correct use Deutz engine equipped with an SCR exhaust after treatment system is required.Here…

1 week ago