Here is a instruction guide on how to repair AGCO POWER EEM4 engine K4144 MPROP control Open circuit trouble.More repair case for JCB,please refer to:JCB Trouble Repair
Related Content:
2023 AGCO EDT (Electronic Diagnostic Tool) v 1.123 v1.75 Free Download
WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download
2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11
The EEM4 system has detected an open circuit on the high pressure pump control (MPROP).
Possible causes are:
The solenoid valve connector is defective.
The solenoid valve wiring is defective.
The solenoid valve is defective.
Reaction in EEM
The FC is stored and the warning lamp is activated. The CAN message indicates active fault.
Solution
First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:
Check the solenoid valve wiring, the connectors and the contact surfaces of the connector pins (possible oxidation).
Measure between the low side from the MPROP connector to the ECU connector pin, to see if there is a fault cable.
Check the operation with another MPROP solenoid valve to see if the solenoid valve is defective.
PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution Related Contents: 2024 InPower V14.5…
The function identifies the exhaust temperature and indicates malfunction in the exhaust system. The evaluation…
MTU DiaSys diagnostic software is professional on MTU engine diagnostics and programming.But seems that is…
This instruction show you guide on how to use JPRO Diagnostic to do aftertreatment injector…
There are several different diagnostic vendor adapter support Hyster and Yale forklift truck,here show you…
For correct use Deutz engine equipped with an SCR exhaust after treatment system is required.Here…