1.DESCRIPTION OF CODE REGISTRATION

HINT:

*Recognition code registration is necessary when replacing door control transmitter or door control receiver.

*Add mode is used to register new recognition codes while still retaining codes already registered. *This mode is used when a new transmitter is added. If the number of registered codes exceeds 6, the previously registered codes will be cleared in order, starting from the first registered code.

*Rewrite mode is used to clear all the previously registered recognition codes in order to register new recognition codes. This mode is used when the transmitter or door control receiver is replaced with a new one.

*Confirmation mode is used to confirm how many recognition codes have already been registered before registering any additional recognition codes.

*Prohibition mode is used to clear all the registered codes and disables the wireless door lock function. This mode is used when the transmitter is lost.

*The registration procedures must be performed in order,

 

2.REGISTER RECOGNITION CODE (USING TECHSTREAM)

HINT:

For detailed procedures, refer to the prompts on the Techstream screen. The number of currently registered codes can be checked on the first screen of Wireless Code Registration.

Turn the ignition switch to ON.

Enter the following menus: Body Electrical / Main Body / Utility / Wireless Code Registration.

Press both the lock and unlock switches at the same time for 1 to 1.5 seconds.

Press either switch for more than 1 second within 3 seconds.

Check the response to the registration completion.

 

If the lock-unlock operation occurs twice, the registration of the recognition code has failed. Perform the registration procedures again from the beginning.

  • If registering another transmitter, repeat the procedures after the Techstream operation. All 6 recognition codes can be registered consecutively.

(f) Perform either of the following to complete the registration of the recognition codes:

  • Use the Techstream to send a completion command.
  • Disconnect the Techstream.

 

3.REGISTER RECOGNITION CODE (USING SWITCH OPERATION)

(a) Make sure the following conditions are met.

  • No key is inserted in the ignition key cylinder.
  • The driver side door is open (the other doors are closed).
  • The driver side door is unlocked.

(b) Insert and remove the key into/from the ignition key cylinder twice (Insert-Remove-Insert-Remove) within 5 seconds.

HINT:

The procedure should end with the key removed.

(c) Perform the following operations within 40 seconds.

(1) Close and open the driver side door twice (Close ► Open » Close ► Open).

HINT:

The procedure should end with the door open.

(2) Insert and remove the key into/from the ignition key cylinder (Insert -» Remove).

HINT:

The procedure should end with the key removed.

(3) Close and open the driver side door twice (Close —* Open —* Close —» Open).

HINT:

The procedure should end with the door open.

(4) Insert the key into the ignition key cylinder and close all the doors.

(d) Perform the following operations within 40 seconds.

(l)Turn the ignition switch to ON and then off at approximately 1 second intervals. Operate the ignition switch according to the number of times shown below.

HINT:

If the number of ignition switch ON – off operations is 0, 4, or 6 or more, there will be no response (power door lock and unlock operation) to show which mode has been selected.

(2) Remove the key from the ignition key cylinder.

(e) Check that the response begins within 5 seconds after completing the above step, and that the response matches the selected mode.

NOTICE

After the system has been set to prohibition mode, enter the confirmation mode and check that the number of registered keys is 0.

HINT:

In confirmation mode, the lock-unlock operation will occur once for each recognition code that has been registered. For example, if 2 recognition codes have been registered, the lock-unlock operation will occur twice.

In confirmation mode, if no recognition codes have been registered, the lock-unlock operation will occur 11 times.

If confirmation mode or prohibition mode is selected, the operation ends after the response to the selected mode completes.

(f) If add mode or rewrite mode is selected, perform the following procedures.

Press a single switch (lock or unlock) within 5 seconds.

Check that the response begins within 3 seconds after completing the above step, and that the response indicates that registration has been completed correctly.

HINT:

  • If the lock-unlock operation occurs twice, the registration of the recognition code has failed. Perform the registration procedures again from the beginning.

If registering another transmitter, repeat the procedures after the mode selection response confirmation. All 6 recognition codes can be registered consecutively.

(g) Perform either of the following to complete the registration of the recognition codes:

  • Open a door.

• Insert the key into the ignition key cylinder.

auto

Recent Posts

Doosan Stage V Machine U0632 CAN-Receive-Frame Timeout Error Solution

This instruction show you guide on how to solve Doosan Stage V machine U0632 timeout…

3 days ago

CASE IH 20 Series Combine Park Brake Piston Travel and Adjustment

This instruction show you guide on how travel and adjust park brake piston for CASE…

5 days ago

How to Replace Purge Valve for Fendt 900 Vario COM III Tractor?

Here is the instruction show you guide on how to replace purge valve for Fendit…

1 week ago

How to Solve JCB SPN 102, FMI 1 Boost Pressure Sensor: Pressure Below Normal

Here is the instruction show you guide on how to JCB machine SPN 102,FMI 1…

2 weeks ago

How to Install Preconcave for CLAAS Lexion 480 Combine

This instruction show you guide on how to install preconcave for CLAAS Lexion 480 combine…

2 weeks ago

Deutz EMR3 Trouble Code 78/ 190 Speed Sensor Signals Out of Phase

This instruction show you guide on how to solve Deutz EMR3 trouble code 78/ 190 EngMOfsCaSCrS Speed…

2 weeks ago