Heavy Equipment Repair

Perkins 800 Series Engine Water Temperature Regulator Housing Remove and Install

This instruction show you guide on how to remove and install water temperature regulator housing.

 

Related Contents:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

 

Removal Procedure

1 Drain the coolant from the cooling system into a suitable container for storage or disposal.

Refer to Operation and Maintenance Manual,“Cooling System Coolant – Change” for the correct procedure.

 

2.Remove bolts (1) and remove outlet connection (2).

3 Remove joint (3) and remove water temperature regulator (4). Note the orientation of the water temperature regulator for installation.

4 Loosen the hose clamp and disconnect hose (8) from water temperature regulator housing (6).

5 Remove bolts (7) and remove water temperature regulator housing (6) from the cylinder head.

6 Remove joint (5).

 

 

Installation Procedure

1 Inspect the water temperature regulator for wear, damage and correct operation. Refer to Systems Operation,Testing and Adjusting,“Water Temperature Regulator – Test” for more information. If necessary, replace the water temperature regulator.

2 Ensure that the mating surfaces of the outlet connection, the water temperature regulator housing and the cylinder head are clean and free from damage.

3 Position bolts (7) and a new joint (5) onto water temperature regulator housing (6).

4 Position water temperature regulator housing

(6) onto the cylinder head. Tighten bolts (7) to a torque of 18 N·m (13 lb ft).

5 Install water temperature regulator (4) to water temperature regulator housing (6). Ensure the correct orientation of the water temperature regulator.

6 Position a new joint (3) and outlet connection (2) onto water temperature regulator housing (6).

7 Install bolts (1). Tighten the bolts to 18 N·m (13 lb ft).

8 Connect hose (8) to water temperature regulator housing (6). Tighten the hose clamps securely.

9 Fill the cooling system with coolant to the correct level. Refer to Operation and Maintenance Manual, “Cooling System Coolant -Change” for the correct procedure.

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

 

auto

Recent Posts

How to Install Left-hand Drum Bearing Assembly for CLAAS LEXION 480

Here is the instruction show you guide on how to install the left-hand drum bearing…

2 weeks ago

How to Remove and Replace Loader Lift Ram for JCB 3CX 4CX Machine

This instruction show you guide on how to remove and replace loader lift ram for…

2 weeks ago

How to Solve Caterpillar C9 Engine Vehicle Speed Loss of Signal Error?

This instruction show you guide on how to solve Caterpillar C9 engine 31 84-1 fault…

2 weeks ago

How to Perform Accumulator Charging/Discharging for JCB 3CX,4CX

This instruction show you guide on how to charge and discharge accumulator for JCB 3CX,…

4 weeks ago

How to Solve PowerCommand PCC2300 Fault Code 143 Low Oil Rifle Pressure

This instruction show you guide on how to to solve PowerCommand PCC2300 trouble code 143…

4 weeks ago

How to Solve HINO J05E Engine P007B Intake Air Temperature Sensor Error

Here is the instruction show you guide on how to solve HINO J05E engine P007B…

1 month ago