This article show a guide on how to use Nissan Consult 3 Plus to program keyless remote (T31/C11/K12).Hope it helps,and if you want to know more about Nissan Consult 3 Plus,check:Nissan Consult 3 Plus Projects.
Related Contents:
Nissan Consult 3 Plus Software Download
How to Install Nissan Consult 3 III Plus Diagnostic Software
Nissan Consult 3 Plus Clone Interface
Procedures:
1.From the CONSULT-III plus “All DTC” screen, select the “BCM”.
2.Select “MULTI REMOTE ENTRY”.
3.Select “Work Support”.
4.When the next screen appears, (section shown below) select “REMO CONT ID REGIST” function to program the remotes.
ID Code Entry Procedure
STEP 1
Close all doors (Observe the operation of the interior light with each door to ensure the door switches are OK).
STEP 2
Operate lock using the driver side door lock and unlock switch (on P/Window swassy.)
STEP 3
1.Remove and insert the key into the ignition key 6 times within 10 seconds (turning the key barrel switch from OFF to ON counts as 1 time).
2.Hazard warning lamp blinks and all door unlocks.
NOTE:On the sixth key insertion, keep the key in the cylinder with the key barrel switch ON.Does the hazard lamp blink and all doors unlock?YES >> GO TO STEP 4.NO >> GO TO STEP 1.
STEP 4
Within 3 seconds after the hazard lamp blinks and all door unlocks, turn ignition switch to the ACC position and operate lock using the driver side door lock and unlock switch.
STEP 5
1.Press the lock or unlock button of the keyfobto be added.
2.All doors unlock simultaneously.
3.Hazard warning lamp blinks and all door unlocks.
4.Key ID is registered.
Is key ID registered?
YES-1 >> When adding a keyfob: GO TO STEP 6.
YES-2 >> When ending registration: GO TO STEP 8.
NO >> GO TO STEP 1.
STEP 6
Operate lock using the driver side door lock and unlock switch.
STEP 7
1.Press the lock or unlock button of the keyfobto be added.
2.All doors unlock simultaneously.
3.Hazard warning lamp blinks and all door unlocks.
4.Key ID is registered.
Is key ID registered?
YES-1 >> When adding a keyfob: GO TO STEP 6.
YES-2 >> When ending registration: GO TO STEP 8.
NO >> GO TO STEP 6.
STEP 8
Open the all doors >> REGISTRATION END.
When you use IDSS diagnostic scan to do some function,it may occur communication error.Sometime you…
Deutz engine EOL test (end of line) is required to ensure the EAT functionality. Conditions…
This instruction show you guide on how to solve Scania truck articulation control system ACS…
Magneti Marelli 49FB – Fiat ECU Pinout More ECU PINOUT Components: ECU Modules Repair…
After ECU reparogramming,it is necessary to write new engine number and machine ID into ECU.So…
PCC1302 PowerCommand Low Coolant Level (Warning or Shutdown) Solution Related Contents: 2024 InPower V14.5…