Heavy Equipment Repair

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You are advised to use this function when adding or removing:

 

One electrohydraulic valve at the rear of the tractor, or

The electrohydraulic valves at the front of the tractor, or

The front linkage electrohydraulic valve.

 

Preparations:

AGCO EDT 2024

AGCO 2×4 CANUSB

 

 

Important:

For modifications to the hydraulic configuration, the label codes for the linkage controller must be updated.

 

Procedure

1 Select “Change the identifier of all head valves” A then “Start” B

2 Select “the maximum number valve connected on the bus” C

3 Select the maximum number of electrohydraulic spool valves at the front of the tractor D

No electrohydraulic spool valves at the front = 0

With 1 electrohydraulic spool valve at the front = 1

With 2 electrohydraulic spool valves at the front = 2

4 Specify whether the tractor has a front linkage E

Without front linkage = 0

With front linkage = 1

5 Disconnect all electrohydraulic valves from the tractor then “Validate” F

6 Connect rear electrohydraulic spool valve no. 1 using connector X33 – Connector for the electrohydraulic spool-valves supply and X240 – Termination connector for an electrohydraulic spool valve (120-ohm resistor).Select “Refresh” G once the connection to valve no. 1 has been established

 

7 The following message appears: “Auxiliary spool valve no. 1 is correctly configured”. Press “Validate” H to move on to the next electrohydraulic valve.When changing the identification number of the valve, it may be necessary to switch off the ignition.

8 Repeat the above configuration steps for all the valves, following the procedure set out in the diagnostic tool and the sequence of electrohydraulic spool valves.

Rear spool valve no. 1 = 1

Rear spool valve no. 2 = 2

Rear spool valve no. 3 = 3

Rear spool valve no. 4 = 4

Rear spool valve no. 5 = 5

Rear spool valve no. 6 = 6

Front spool valve no. 1 = 7

Front spool valve no. 2 = 8

Front linkage valve = 9

9 Once the procedure for configuring the valves is complete, reconnect all the electrohydraulic spool valves for the tractor to their respective connectors/harnesses

 

AGCO EDT Electronic Diagnostic Tool 1.128 Diagnostic Software

 

auto

Recent Posts

Perkins 400A 400D Industrial Engine Crankshaft Rear Seal Remove and Install

This instruction show you guide on how to remove and install crankshaft rear seal for…

2 days ago

JPRO Diagnostic Software SCR Performance and System Test on Cummings

This instruction show you guide on how to use JPRO diagnostic to do SCR performance…

6 days ago

Yale ERP15-20VT G807 Forklift Truck Master Cylinder Removal and Disassemble Guide

Here is the instruction show you guide on how to remove and disassemble master cylinder…

1 week ago

How to Solve Deutz EMR3 71 / 2791 / EGRCD_SigNpl Error?

This instruction show you guide on how to solve Deutz EMR engine 71 / 2791 /…

2 weeks ago

How to Solve Allison 3000 & 4000 Gen5 P0731 Incorrect 2nd Gear Ratio?

Here is the instruction show you guide on how to repair P0731 incorrect 2nd gear ration…

2 weeks ago

How to Use CAT ET 2025A to Test Misfire Detection for Caterpillar Machine?

Here is the how to use guide on Caterpillar machine misfire detection test by CAT…

2 weeks ago