JCB Tier 4 Air Filter Pressure below Normal Error Solution

This illustration show the solution JCB stage V Tier 4 SPN107 FMI 18,air filter pressure below normal error.

Related Contents:

WinEEM4s JCB Service Tool 2.7.2 2.6.1 Free Download

2024 JCB ServiceMaster 4 v24.3.1 Free Download for Win 10 Win11

2017 JCB Parts Plus+ and Repair Service Manual Free Download

 

Description

The air filter pressure is below normal operation range.

 

Possible causes are:

The air filter is blocked.

The air filter pressure sensor wiring is defective.

The air filter sensor is defective.

 

Reaction in EEM

The FC is stored and the warning lamp is activated. The CAN message indicates active fault.

 

Solution

Change the air filter.

To check the electrical defects, check intake the air filter pressure sensor, the sensor wiring and the controller input: First save the error log and then erase it. Restart the ECU after erasing the error log. If the fault occurs again during the next driving cycle, check the following paths:

 

Check the air filter pressure sensor wiring, the connectors and the contact surfaces of the connector pins (possible oxidation)

.

Check the operation with another air filter pressure sensor to see if the air filter pressure sensor is defective.

 

More repair case for JCB,please refer to:JCB Trouble Repair

auto

Recent Posts

How to Remove Second Tank for CLAAS AXION 960-920 Tractor

This instruction show you guide on how to remove second tank for CLAAS AXION 960-920…

3 days ago

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

5 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

1 week ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

2 weeks ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

2 weeks ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

3 weeks ago