How to Use DMS-5 to Calibrate Swash Plate Angle

This instruction show you guide on how to use DMS-5 diagnostic software to calibrate swash plate angle for Doosan excavator.

 

Related Contents:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download

Daios Doosan EPC Excavator Part Catalog 2017 Download & Installation

 

Procedures:

Swash Plate Angle Calibration

<Pump Swash plate angle sensor calibration concept>
1. In the case of VBO, the flow rate of the pump is controlled based on the swash plate angle sensor value, so the
sensor value must be measured at the maximum/minimum of the swash plate angle and calibration to the Software
reference value for accurate flow control.
2. That is, by measuring the swash plate angle sensor output(voltage) when the pump is at the maximum/minimum
position to calibrate the maximum/minimum swash plate angle value. 3.
3. For example, theoretically, the sensor output voltage at the maximum/minimum swash plates is at 4.5/0.5V, but if
the actual sensor value is 4.4/0.4V, it will be calibrated at 4.4V and the minimum at 0.4V.

<Caution>
1. The green light meaning of the displayed value is an indication that the tolerance for mounting the pump angle
sensor is within range, meaning no calibration is required. It is recommended that the measurements be calibration for
precise control.
2. That is, click ‘APPY’ after front pump calibration, and then click ‘APPLY’ again apply after rear pump calibration to save
the calibration value for each pump.
3. If the window displaying the value with red color, the pump is suspected to be defective so please contact Doosan regional service manager

Swash Plate Angle Calibration Setting before a test

 

Swash Plate Angle Calibration Process:

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save
the calibration value

1.If it’s green – Click the Save button to save the calibration value.
2.If it’s red – Recalibration is performed 2-3 times, and if it continues to be red contact your
regional service manager.If it turns to green light after 2-3 times trials during recalibration, click the Save button to save the calibration value.

 

auto

Recent Posts

How to Replace Fuel Tank Breather Filter Element for Liebherr R9600 Excavator

Here is the instruction show you guide on how to replace fuel tank breather filter…

1 week ago

FENDT 900 Vario COM III B092 Boost Pressure/Temperature Sensor

FENDT 900 Vario COM III tractor Component B092 - Sensor, charge air pressure/temperature reports the boost…

2 weeks ago

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution

Deutz EMR3 Engine Trouble Code 87 / 97 / FlFCD WATER IN FUEL Solution Error description…

2 weeks ago

Kubota L3301 L3901 Tractor Hydraulic Flow Test Guide

This instruction show you guide on how to perform hydraulic flow test for Kubota L3301…

3 weeks ago

Bendix AutoVue FLC20 Camera LDW Configuration by JPRO

This instruction show you guide on how to configure Lane Departure Warning for Bendix AutoVue…

4 weeks ago

How to Solve AGCO Machine SPN 102 FMI 03 Boost Pressure Sensor Defect HIGH

This instruction show you guide on how to solve AGCO machine SPN102 FMI03 boost pressure…

4 weeks ago