How to Use Deutz SerDia2010 Trip Recorder Function?

Deutz SerDia2010 trip recorder holds the record for the measured values given in SerDia2010 and counts them.It also includes load spectrum.

There are 3 different types of counters in the trip recorder:
1. Counting stage 1, an X / Y / Z or 3D chart
2. Counter stage 2 is an X / Y-value table
3. Counter stage 3/4 counts up the number of states spent only for the specific measurement..
“Confirm selection” by pressing the button of the corresponding counter is stored locally.

Related Contents:

2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download

Deutz Diagnostic Kit DECOM for Deutz Engine

 

 

Counter Stage 1:
1.Load Spectrum
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
The structure of the bottom of the window measurement is shown as follows:

 

2.) Oil pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]
3.) Boost pressure trip recorder (analogous to 1)
X-Axis: Engine Speed [1/min]
Y-Axis: Engine Load [%]
Z-Axis. Time [h]

Counter State 2:
Counter stage 2.2 records the coolant temperature over the engine over the time (hours of
operation).

In the lower window following table is shown:

X-Value is the time [h] (upper row)
Y-Value the coolant temperature (CT) [°C] (lower row)
The counter-Level 2 diagrams are to read as follows:
-30 °C < CT < 70 °C 0,0 Hours
70 °C < CT < 85 °C 0,0 Hours
85 °C < CT < 100 °C 0 Hours –>
100 °C < CT < 115 °C 0,45 Hours –>
115 °C < CT < 130 °C 0,0 Hours –>
The following collections may vary with the connected motor / EAT System !!
Counter stage 2.2 records the boost temperature over the time.
Counter stage 2.3 records the coolant temperature over the time.
Counter stage 2.4 records the SCR-Pump pressure over the time.
Counter stage 2.5 records the injection pressure over the time.
Counter stage 2.6 records the ambient air pressure over the time.

Counter Stage 3:
For the measured values displayed in the lower window will display the time in the respective
states in seconds.

 

Counter State 4:
For the measured values displayed in the lower window will display the time in the respective
states in seconds, for example:
· Coolant temperature over limit
· Boost temperature over limit
· etc.

Notice:This function is available at Competence Class Level 2.

auto

Recent Posts

JCB 200X Series Machine Reduced Power Mode Engine Derate

JCB Engine Fault Derate When a fault is detected, the ECU determines the severity of…

2 days ago

Liebherr ECU2 D966 D9512 Engine P1162 Fault Code Solution

Here is a instruction show you guide on how to solve Liebherr ECU 2 D966…

5 days ago

AGCO EEM5 DEF Suction Module Tank sensor (CAN)

AGCO EEM5 DEF Suction Module Tank sensor (CAN) The DEF suction module with the CAN-bus…

1 week ago

How to Remove Threshing Drum for CLAAS Lexion 480 Combine

This instruction show you guide on how to remove the threshing drum for CLAAS Lexion…

1 week ago

Hitachi ZX890-7 Excavator Service Menu Display

This instruction show you guide on how to display service menu for Hitachi ZX890-7 excavator.…

2 weeks ago

JCB 200 Series Excavator ATS Setup and Calibration Procedure

Here is the instruction show you guide on how to do Advanced Tool Select and Basic…

2 weeks ago