How to Solve Perkins 1106D Generation CID 0004 FMI 05 Open Circuit

This illustration show you guide on how to solve Perkins 1106D electric power generation (EPG) CID 0004 FMI 05 open circuit problem.

Related Contents:

Perkins EST 2024A & 2023A & 2019A Software Free Download

Perkins SPI2 2018A EPC+Service Manual Free Download

Perkins Communication Adapter 3

 

This diagnostic code indicates an open circuit (low current) in either the solenoid or the wiring for the electronic unit injector for No. 4 cylinder.

The Electronic Control Module (ECM) detects the following condition:
• A low current condition (open circuit) for each of five consecutive attempts to operate
• Battery voltage is higher than 9 volts for 2 seconds.

System Response:
The ECM will log the diagnostic code. If equipped, the diagnostic lamp will flash.

Possible Performance Effect:
The engine will have low power and/or rough running.

Troubleshooting:
When the “Injector Cutout Test” is performed, a faulty electronic unit injector will indicate a low reading in comparison with the other electronic unit injectors.

An electrical fault can prevent the electronic unit injector from operating. An open circuit in the wiring that is unique to the electronic unit injector will prevent that individual electronic unit injector from operating.

An open circuit in common wiring within the ECM can prevent the three electronic unit injectors that share that common wiring from operating.

The ECM will continue to attempt to operate the electronic unit injector after the diagnostic code has been logged but an open circuit will prevent the operation of the electronic unit injector.

Perform the following diagnostic procedure: “Injector Solenoid Circuit – Test”

 

More trouble repair case for Perkins,pls refer to:Perkins Trouble Repair

auto

Recent Posts

AGCO EEM5 DEF Suction Module Tank sensor (CAN)

AGCO EEM5 DEF Suction Module Tank sensor (CAN) The DEF suction module with the CAN-bus…

18 hours ago

How to Remove Threshing Drum for CLAAS Lexion 480 Combine

This instruction show you guide on how to remove the threshing drum for CLAAS Lexion…

3 days ago

Hitachi ZX890-7 Excavator Service Menu Display

This instruction show you guide on how to display service menu for Hitachi ZX890-7 excavator.…

6 days ago

JCB 200 Series Excavator ATS Setup and Calibration Procedure

Here is the instruction show you guide on how to do Advanced Tool Select and Basic…

1 week ago

How to Solve Liebherr D966 D9512 Trouble Code P1161 Resistance Error

Here car-auto-repair.com show you guide on how to solve P1161 trouble code on resistance error…

2 weeks ago

AGCO EEM 5 Dosing Module

AGCO EEM Dosing module   Description The dosing module (DM) is installed in the exhaust…

2 weeks ago