Here is the instruction show you guide on how to solve Bobcat engine DCU P2A8C and P2A8D DEF pump motor speed duty low/high error.
Related Contents:
Bobcat Engine Analyzer ECU DCU 2023
2023 Bobcat Service Analyzer 91.15 91.05 Diagnostic Free Download
1) Overview
U004374-23
1 Electric problem (Supply module connector)
2 Electric problem (Wiring harness DCU to supply module,Supply module)
3 Electric problem (DCU connector, DCU)
1
2) Component Location
2
3) Condition for Running Diagnostic
When pump motor is normal
4) Condition for Setting the Fault Code
When the sensor value (raw duty cycle) is less than 4%
5) Condition for Clearing the Fault Code
When the sensor value (raw duty cycle) is greater than 4%
6) Check List
More repair topic for Bobcat,please refer to:Bobcat Excavator Repair
| Step | Inspection | Standard Value | YES | NO |
| 1 | P2A8C/P2A8D is occurred on diagnostic tool? | Step 2 | ||
| 2 | After let the machine be in safety area and turn off the key switch | Step 3 | ||
| 3 | Check sensor connection Connection problem? | Do necessary repair | Step 4 | |
| 4 | Check DCU connection Connection problem? | Do necessary repair | Step 5 | |
| 5 | Check the DCU voltage related pin connection and harness. Pin or connection problem? | Do necessary repair | Step 6 | |
| 6 | Check continuity and electrical insulation Electrical problem? | Fix harness | Change SM |
This instruction show you guide on how to solve Doosan and Bobcat Electric problems can…
It is necessary to do driver installation for JCB DLA 2.0 diagnostic kit,otherwise it can…
Here is the instruction show you guide on how to solve Deutz EMR3 engine fault…
This instruction show you guide on how to solve AGCO machine trouble code 138 SPN…
Here is the instruction show you guide on how to install the left-hand drum bearing…
This instruction show you guide on how to remove and replace loader lift ram for…