Categories: Excavator Repair

How to Adjust Valve Clearance for Komatsu Excavator PC130

This is a guide focus on how to adjust valve clearance for Komatsu excavator PC130.All workshop manual and part catalogue you can refer to:Komatsu CSS Full Set 2018 2014 Parts Viwer Free Download

 

Note:Stop the machine on a level ground and lower the work equipment to the ground.

Adjust the valve clearance under the following condition.
Engine coolant temperature: Normal temperature

 

Procedures:

1.Open the engine hood and remove maintenance step (1) and air supply hose (2) on the engine

2.Remove cylinder head cover (4).

3.Remove plate (5) on the starting motor and insert gear B1.

4.Remove compression top dead center TDC check plug (6) from the flywheel housing.
Rotate the crankshaft forward with gear B1 and set it so that you can see the white mark of the flywheel.

When the No. 1 cylinder is at the compression top dead center, the rocker arm of the No. 1 cylinder can be moved by the valve clearance with the hand. If the rocker arm cannot be moved, the No. 1 cylinder is not at the compression top dead center. In this case, rotate the crankshaft one more turn.

auto

Recent Posts

How to Remove Second Tank for CLAAS AXION 960-920 Tractor

This instruction show you guide on how to remove second tank for CLAAS AXION 960-920…

3 days ago

Doosan Excavator P0408 Maximum EGR Rate Governor Deviation Error Solution

This instruction show you guide on how to solve Doosan excavator P0408 maximum EGR rate…

6 days ago

How to Calibrate 2403 Steering Valve for Fendt 800 S4 Tractor

Here is the instruction show you guide on how to calibrate 2403 steering valve for…

1 week ago

Massey Ferguson Tractor Electrohydraulic Spool Valves Configuration

This function requires all connectors to be disconnected from all electrohydraulic valves on the tractor.You…

2 weeks ago

How to Remove Center Joint and Center Frame for HITACHI Hitachi EX5600-7B

This instruction show you guide on how to remove center joint and center frame for…

2 weeks ago

How to Repair Doosan Machine P0100 DTC Signal Error

How to solve Doosan heavy duty machine P0100 fault code signal error of air mass…

3 weeks ago